Technical Data - Inakustik REFERENZ AC-3500P Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPER ATION MANUAL
REFERENZ AC-350 0P
POWER CABLES / POWER BARS
When using multiple power boards and extension cables, pay special attention to the DIN VDE 0100 part 420, para. 4.1 (risk of fire in electrical
installations). Furthermore, the VDE 0100-410:2007-06 also requires short breaks of 0.4 s for the TN system. The temperature of the cable
may rise in such cases to the point of causing a fire. Therefore, the following applies to ALL power boards: Do not connect them in a row and
do not use if covered!
For power bars with two-pin relay, the units connected to the switched sockets will be reliably and 2-pin (also known as all-pin) disconnected
from the mains. However, the absence of voltage in the unit is only ensured when the mains plug is disconnected.
DESCRIPTION
Image quality and audio quality start at the mains socket. Unfortunately, there is usually quite a large load on the mains power, causing inter-
ference. Many digital devices and so-called switching power supplies in particular generate severe distortions in the mains power, making it
difficult for the devices connected to function properly, and obscuring the sound that should be emerging from the hi-fi chain.
This high-quality mains power filter was designed especially for high-end applications. Its specially developed filter network, which in contrast
to conventional filter designs operates parallel to the power supply, conducts the majority of the distortion to earth. The main advantage of this
concept is that there are no components connected to the mains power in series, which would otherwise compromise the power and dynamics.
This ensures the acoustic foundation is left intact, and the filter ensures subtle facets of the music are reproduced more clearly.
Features:
Highly effective central parallel filter
Symmetrical star distribution
High-quality sockets
Dampened sub-chassis
Surge protection
All-pole mains disconnection
Aluminium front
Metal housing
Scope of delivery
Mains power filter Reference AC-3500P
Power cord
Operating manual
GETTING STARTED
Unpack the device and put it in its intended place. Please observe the safety instructions when doing so.
Connect the devices to the AC-3500P in accordance with the respective operating instructions. The star distribution allows the devices (ampli-
fier, source, DAC, etc.) to be set up in any order.
When you wish to connect your system with the correct phase, the markings on the sockets will help you to do so. Please ask your specialist
retailer about this.
Finally, connect the mains power filter to the mains socket.
Once you have checked all the connections again, you can switch on the mains power filter at the front.
6

Technical Data

Number of outputs: 6
Mains connection: IEC C-20 socket
Operating voltage: 100-250V AC / 50-60 Hz
Maximum operating current: 16 amps in total
Maximum power input: 3680 watts (230 V AC / 16 amps)
Dimensions: approx. 450 x 370 x 160 mm
Weight: approx. 12.8 kg