Malfunctions And Troubleshooting; Technical Data - NOVELCA 3141017 Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MALFUNCTIONS AND TROUBLESHOOTING

Minor faults are often sufficient to cause a malfunction. In most cases, you will be
able to correct these faults easily yourself. Please start by referring to the following
table before contacting your retailer for technical support. If you are unable to
correct the situation, please contact your retailer. Please note that improperly
conducted repairs will void your warranty and may cause additional expenses.
FAULT/MALFUNCTION
Pump does not run
Pump runs but does
not pump
Delivery rate too low
Pump makes
a loud noise

TECHNICAL DATA

Model
JDP550PD
Rated voltage
115 V, 60 Hz
Rated power
550 W
Protection type
1PX8
Maximum flow rate 10,500 L/h
POSSIBLE CAUSE
No voltage
Motor overheats due to:
• liquid temperature too hot
• blocking by foreign bodies
Residual current circuit breaker
(RCCB) triggered
Suction openings blocked
Pump draws in air
Pump blocked by foreign bodies
Delivery height too great
Pressure line diameter too small
Pressure line blocked
Suction openings blocked
Pressure line kinked
Pressure line leaks
Pump draws in air
Cable length
Maximum supply height
Maximum submersion depth
Maximum temperature of liquid 35 °C
Pressure pipe diameter
Pipe connection
REMEDY
Check cable, plug, socket, outlet, fuse, etc.
Eliminate the cause of the overheating
(max. temperature of liquid, see technical
data below)
Activate RCCB;
contact a qualified electrician if RCCB
triggers again
Clean the blockage
Keep the pump at an angle while submerging
Switch the pump on and off several times
in order to expel air
Clean the pump (see cleaning the suction
area on page 5)
Comply with maximum delivery height
(see technical data below)
Use pressure line with larger diameter
Clean the blockage
Clean suction openings
Straighten pressure line
Seal pressure line, tighten threaded
connections
Ensure there is sufficient liquid
Keep the pump at an angle while submerging
3.3 m
24' (7.2 m)
22' (7 m)
1" (2.54 cm), 1 ¼" (3.17 cm),
½" (1.27 cm)
7

Publicité

Table des Matières
loading

Table des Matières