WARNING
Should overheating occur, or the gas supply
fail to shut off, shut off the manual gas valve to
the appliance before shutting off the electrical
supply.
11. Never attempt to repair damaged parts. Always have them
replaced by a qualified service agency.
12. Never attempt to repair the furnace yourself. Seek the help of
a qualified service person.
13. Never restrict the ducting installed by your trailer manufacturer.
To do so could cause improper furnace operation.
14. Avoid direct contact with the outlet registers or vents as they
will become hot during the heating cycle.
15. Do not install air boosters in the duct system. Such devices
will cause the furnace to cycle on limit and to have erratic sail
switch operation.
16. Clothing or other flammable material should not be placed on
or near the appliance.
17. Always follow the Operating Instructions. Do not deviate from
the step-by-step procedures.
18. When considering add-on rooms, porch or patio, attention
must be given to the venting of your furnace. For your safety,
do not terminate furnace vent inside add-on rooms, screen
porch or onto patios. Doing so will result in products of
combustion being vented into the room or occupied areas.
19. In any installation in which the vent of this appliance
can be covered due to the construction of the RV or
some special feature of the RV such as slide out, pop-
up etc. always ensure that the appliance cannot be
operated by setting the thermostat to the positive "OFF"
position and shutting off all electrical and gas supply to
the appliance. Never operate furnace with vent covered.
Your furnace should be inspected by a qualified service
agency yearly before turning the furnace on. Particular
attention should be given to the following items:
1.
Inspect furnace installation and vent termination to be sure
furnace is properly secured in place, that vent terminates to
the atmosphere and that vent tubes overlap properly. (See
installation manual supplied with furnace.)
2.
Inspect chamber and venting to assure that these components
are physically sound, without holes or excessive corrosion and
that the installation and/or reinstallation is in accordance with
Suburban's Installation Instructions. (Reference installation
manual supplied with furnace.)
WARNING
It is imperative that the products of combustion
be properly vented to atmosphere and that all
combustion air supplied to burner be drawn
from outside atmosphere.
3.
Check the base on which furnace is mounted. Be sure it is
physically sound, void of any sagging, deterioration, etc.
4.
Inspect furnace, the venting, ducting and the gas piping to furnace
for obvious signs of deterioration. Correct any defects at once.
5.
Inspect combustion chamber for restrictions in exhaust or
intake. It is imperative that the flow of intake combustion air
and the flow of exhaust gases being expelled to the outside
atmosphere not be obstructed. Any soot or loose debris
should be blown out using compressed air. (See Figure 3.)
6.
Inspect all gaskets. If any gaskets show signs of leakage or
deterioration, replace them. Safe operation of the furnace
depends on all gaskets being tight.
7.
Inspect return air inlet openings to the furnace. Remove any
restrictions to assure adequate air flow.
OPERATING INSTRUCTIONS
WARNING
Do not operate furnace while vehicle is in motion
or being towed.
NOTE: During initial firing of this furnace a burn-off of excess
paint and oils remaining from manufacturing process may
cause "smoking" for 5 - 10 minutes.
FOR YOUR SAFETY
READ BEFORE OPERATING
WARNING
If you do not follow these instructions exactly,
a fire or explosion may result causing property
damage, personal injury or loss of life.
A. This appliance does not have a pilot. It is equipped with
an ignition device which automatically lights the burner.
Do not light the burner by hand.
B. BEFORE OPERATING smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•
Extinguish any open flame.
•
Evacuate all persons from the vehicle.
•
Shut off the gas supply at the gas container or source.
•
Do not touch any electric switch or use any phone or
radio in the vehicle.
•
Do not start the vehicle's engine or electric generator.
•
Contact the nearest gas supplier or qualified service
technician for repairs.
•
If you cannot reach a gas supplier or qualified service
technician, contact the nearest fire department.
•
Do not turn on the gas supply until the gas leak(s) has
been repaired.
C. Do not use this furnace if any part has been under
water.
A flood damaged furnace is extremely
dangerous. Attempts to use the furnace can result in
fire or explosion. A qualified service agency should be
contacted to inspect the furnace and to replace all gas
controls, control system parts, electrical parts that have
been wet or the furnace if deemed necessary.
OPERATING INSTRUCTIONS
1. STOP! Read User's Information Manual supplied with
furnace.
2. Turn the manual valve (if so equipped) or the valve at
the outside Propane tank to the "OFF" position. See
Figure 4. Do not force.
3. Set thermostat above room temperature to begin
blower operation. A slight delay will occur before the
blower comes on. Allow blower to run for 5 minutes for
combustion chamber purge cycle. If blower does not
come on or stops before ignition cycle, go to shut down
and contact your dealer or a local recreational vehicle
service agency.
4. After 5 minutes, move thermostat lever below room
temperature. Blower will remain on. Wait approximately
2 minutes for blower to go off.
3