Identification

1. Bushing
2. Pull pin
3. Thumb screw
4. Drill adapter

Specifications

Insulation Thickness Range ............... 45 mils to 110 mils
Conductor Size Range ..................... 6 AWG to 750 kcmil
Greenlee / A Textron Company
5. Indicator line
6. Depth stop
7. Scales
(1.1 mm to 2.8 mm)

End Stripping Instructions

Preparation

Ensure cable has a straight, round end before
beginning.

Procedure

1. Determine the conductor type and size, and choose
the appropriate bushing; refer to Table 1. To change
bushings, pull the pull pin and remove the bushing.
Load the appropriate bushing and release the pull
pin.
2. Unfasten the thumb screw and adjust the depth
stop by aligning the indicator line with the desired
strip length on the scale; retighten the thumb screw.
3. Securely attach the drill adapter end to the power
drill.
4. Insert the cable end into the bushing opening and
begin stripping by activating the drill at a slow
speed while providing a slight forward pressure
against the cable end.
5. When the desired strip length is reached, the tool
will stop its forward motion. Continue to activate the
drill for another whole rotation to perform a square
cut on the insulation. Remove the tool from the
cable.
4
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070