ENGLISH
OPERATE THE UNIT BY CA-8
When used in standalone or master/slave mode we strongly advise you to use the
CA-8 "Wired easy controller"
STANDBY BUTTON:
Press this button to start/stop blackout mode on all connected units.
MODE/FUNCTION BUTTONS:
With the MODE button you can select 3 different modes:
 The LED is off: with the FUNCTION button you can select different strobe modes,
like "sound strobe".
 The LED is blinking: with the FUNCTION button you can select different shows.
 The LED is on: (music mode is temporarily switched off)
 Press the FUNCTION button shortly: to change the colors
 Press the FUNCTION button longer: to change the gobos
MAINTENANCE
 Make sure the area below the installation place is free from unwanted persons during servicing.
 Switch off the unit, unplug the mains cable and wait until the unit is cooled down.
During inspection the following points should be checked:
 All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
 Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
 When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
 The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
 In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
 The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
 The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
 Clean with a soft cloth using normal glass cleaning products.
 Always dry the parts carefully.
 Clean the external optics at least once every 30 days.
 Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!