Datalogic S100 Serie Manuel D'instructions page 28

Table des Matières

Publicité

Standard Command
Index (dec) Command Name
Lenght
0x0002 (2)
SP1 Teach TP1
1 octet
0x0002 (2)
SP1 Teach TP2
1 octet
0x0002 (2)
Teach Dynamic
1 octet
0x0002 (2)
Teach Dynamic End
1 octet
0x0002 (2)
Restore Factory Settings
1 octet
0x0002 (2)
Confirm Maintenance
1 octet
0x0002 (2)
Disable/enable emission
1 octet
0x0002 (2)
Start / Stop Ping
1 octet
Events
Event code (dec)
Event name
0x4220 (16928)
Temperature underrun
0x4210 (16912)
Temperature overrun
0x5100 (20736)
General power supply fault
0x7710 (30480)
Short circuit - Check installation
PROCESS DATA
Process Data Input
7
6
Not used
DEVICE VARIANT COLLECTION
Product name
Product ID
Product text
S100-PR-5-W00-OZ
10004
Contrast sensor
Process data will not be valid in case of out-of-range values.
(2)
Value (dec)
Description
0x43 (67)
Acquisition FINE: Mark Detection (refer to User's Manual)
0x44 (68)
Acquisition FINE: Background Detection (refer to User's Manual)
0x4B (75)
Dynamic acquisition
0x4F (79)
Exit from Dynamic Detection
Restore factory settings: Device Access Locks, Application Specific Tag, Function Tag, Location Tag, SSC1 Param, SSC2 Param, Delay Settings, Output Type,
0x82 (130)
RGB Selection, Device Temperature Thresholds, Emission Color, Sensitivity
Reset Maintenance parameters (Operating Hours Maintenance, Minimum device temperature since powerup, Maximum device temperature since powerup,
0xA5 (165)
Device Status, Detailed Device Status)
0xB0 (176)
Toggle emission (enable / disable emission)
0xAF (175)
Feature to identify the sensor by yellow LED blinking
Event mode
Appears / Disappears
Appears / Disappears
Appears / Disappears
Appears / Disappears
Byte 0
5
4
3
Event type
Warning
Warning
Error
Error
2
1
0
TEACH-IN
SSC2 (DO pin)
SSC1 (C/Q pin)
821006951 Rev.B
Device status
Remarks
Out of specification
Out of specification
Failure
Failure
Access*
WO
WO
WO
WO
WO
WO
WO
WO

Publicité

Table des Matières
loading