Installation distances
C856W Style
Combustible roof
465
INSTALLATION AGAINST COMBUSTIBLE WALLS
Permitted area for
combustible parts
of the building
400
Combustible wall
300
100
500
730
* There must be a minimum distance of 50 mm/285 mm. If mounting on Contura's corner bracket, the distance must be 56 mm/291 mm.
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
Fire-retardant wall of
brick or concrete
The minimum distance in front of
the stove opening to combustible
parts of the building or interior
decoration must be at least 1,1 m.
E = minimum height to sloped ceiling
from the centre of the chimney
380
Ø150
59
106
Air inlet Ø67
INSTALLATION AGAINST FIREWALLS
750
Fire-retardant wall of
brick or concrete
50*
285*
800
Fire-retardant wall of
brick or concrete
200**
430**
GB
13