Troubleshooting
Following are a few common problems that may occur during operation. Here are some suggestions for easy
troubleshooting:
A. The fixture does not work, no light
1. Check the connection of power and main fuse.
2. Measure the mains voltage on the main connector.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
2. If the DMX LED is on and no response to the channel, check the address settings and
polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the fixture or the
previous one.
4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or
interference to DMX interface circuit.
C. No response to the sound
1. Make sure the fixture does not receive DMX signal.
2. Check microphone to see if it is good by tapping the microphone.
D. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor's drive IC on the PCB might be out of condition.
Fixture Cleaning
The cleaning of internal must be carried out periodically to optimize light output. Cleaning frequency depends
on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause
greater accumulation of dirt on the fixture's optics.
 Clean with soft cloth using normal glass cleaning fluid.
 Always dry the parts carefully.
 Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 day