CONTACTOR UNIT / CIRCUIT BREAKER / WIRING
DIMENSIONS
POWER OUT
(TO FURLER)
POWER IN
( BATTERY THROUGH THERMAL SWITCH)
200
215
Models
Engine
power
12V
EF470-600
700W
Other models (EC70, IBXE, IDXE,...) : Contact us.
WIRING
On picture against the relay
box upon reception. Open it
by unscrewing 4 angle plastic
screws.
Relay Box
(mm)
REMOTE AND VOLTAGE
SELECTOR
REMOTE FUSE
Outside Ø of
electric wires
delivered
24V
12 & 24V
800W
8 mm (5/16")
DO NOT CONNECT ANY WIRE INSIDE THE BOX
Open the bags delivered
in the box and close the
box (1).
Swage the two 16mm² wire
pins (2) of the plug for the
furler wiring.
Swage the 2 pins (2) of the plug
onto the wires that come from the
battery through the circuit breaker.
Choose the pins according to wire
section 25 or 35 mm².
NOTICE DE MONTAGE COFFRET RELAIS / 56012000175 RELAY BOX INSTRUCTION MANUAL
Poids Calc: 168.56 g
Maximum
revolution
speed (rpm)
12 & 24V
30 rpm
Swage the 5 pins of the remote plug (3).
Circuit Breaker
(mm)
Section of
delivered power
breaker
supply wires
amperage
12 & 24V
12V
16 mm²
60A
Circuit
24V
30A
3 /4