Les langues disponibles

INDEX
1. Connections and adjustments p. 6
2. TRANSMITTERS
p. 7 - 9
2.1 Radio codes memorization
2.2 Working time configuration (necessary
if 7/42 channel transmitters are used)
2.3 Radio codes deletion
2.4 Remote memorization of other radio codes
2.5 Remote deletion of a radio code
3. SENSORS
p. 9
3.1 WIND sensor
3.2 RAIN sensor
4. Technical specifications
p. 22
1
Connections and adjustments
1
2
L1
L2
8
RN
9

LED

10
DIP SWITCH
11
AN
LED
12
MOTOR STOPS. The control unit stops the motors at the point of a mechanical
stop through current absorption. The threshold can be set with DIP1 and
DIP2 (table). Attention! Check that the motor only stops at the mechanical
stops (LM = ON): increase the threshold if the motor stops during operation or
decrease if the motor continues to push against the mechanical stops.
WARNINGS
The product at issue must be installed, commissioned and maintained only by licensed and authorised people, respecting the
laws concerning the automatic covers. The system is powered by 24Vdc. Before the connection to the power supply make sure
that the sensors and motors are correctly connected. A faulty connection of the motors (polarity inversion) could damage them
together with the connected mechanical elements. The power supply must supply the required voltage and current according
to the characteristics of the system. The power supply must be compliant with IEC60950-1 and must be protected against the
short-circuit and over-voltage. Use a 2x1.5mm cable to connect the motors and the control unit for length up to 6m, or 2x2.5mm
cable for longer segments. PRODUCT DISPOSAL: at the end of this product's useful life, it must not be disposed of as domestic
waste, but must be taken to a collection centre for waste electrical and electronic equipment. Hereby Teleco automation s.r.l.
declares that the product complies with the essential requirements and other relevant provisions, established by the Directive
1999/5/EC. The declaration of conformity can be consulted on the web site: www.telecoautomation.com/ce. In the view of a constant
development of their products, the manufacturer reserves the right for changing technical data and features without prior notice.
+
18
LM
-
17
16
-
15
+
14
13
P1
1
2
8
24Vdc OUT
9
10
11
12
24Vdc IN
13
14
15
M
16
17
18
DIP1 DIP2
(A)
AN LED WIND SENSOR PULSES
OFF
OFF
1
RN LED RAIN SENSOR ACTIVE
OFF
ON
2
L1
ON
OFF
3
L2
LM
ON
ON
4
P1
Default
6
AERIAL GND
AERIAL RF
RAIN SENSOR (YELLOW, GND)
RAIN SENSOR (BLUE, SIGNAL)
RAIN SENSOR (WHITE,+12V)
WIND SENSOR (BLUE)
WIND SENSOR (BROWN)
MOTOR (CLOSE)
MOTOR (OPEN)
+24Vdc POWER SUPPLY
POWER SUPPLY GND
POWER SUPPLY OUTPUT (GND)
+24Vdc POWER SUPPLY OUTPUT
ON = RAIN ALARM
FLASHING = WIND ALARM
LIMIT SWITCH LED
PROGRAMMING BUTTON
Only in "S"
version