Télécharger Imprimer la page

cedamatic CP.GLISS.RI Mode D'emploi page 15

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
The force of the motor brake is adjusted.
ibra
0: disabled braking - 1:minimum braking - 99: maximum braking
Motor stop delay on limit switch. It is activated only with enabled braking (TSM).
The motor stop delay is adjusted after the triggering of the limit switch. Use a value
calibrated on the gate weight. Use these indicative values:
25
very heavy gates (longer delay)
blc
18
heavy gates
10
average gates
1
light gates (short delay)
0
deactivated (no delay)
MENU
The automatic closure is enabled or disabled
TCA
On: enabled automatic closure
Off: disabled automatic closure
The multi-flat function is enabled or disabled.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse of the
IbL
transmitter have no effect in the opening phase.
Off: disabled multi-flat function.
PP and PED controls are enabled or disable during the TCA phase.
IBCA
On: PP and PED control units are disabled.
Off: PP and PED control units are enabled.
The rapid closure is enabled or disabled
On: rapid closure is enabled. When the gate is open or moving, the photocell ac-
SCL
tivation causes the automatic closure of the gate after 3 s. It is activated only with
:ON
TCA
Off: rapid closure is disabled.
The operating mode of "P.P. Push button" and of the transmitter are selected.
PP
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before the
PRE
starting of the motor.
Off: disabled forewarning flashing light.
During the TCA time, the blinker is enabled or disabled.
LTCA
On: Activated blinker.
Off: De-activated blinker.
The Operator function is enabled or disabled.
On: Operator function enabled.
htr
During operation, the OPEN/CLOSE push-buttons must be kept pressed.
Off: Automatic operation.
The Encoder is enabled or disabled. See section "Operating mode with enabled/
disabled Encoder"
ENC
On: Encoder enabled – The anti-crash sensor is activated.
Off: Encoder disabled – The anti-crash sensor is deactivated.
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
Cvar
Off: Receiver enabled for rolling-code and programmable code transmitters (self-
learning and Dip Switch).
The second radio channel is enabled or disabled on terminals SCA (fig.2).
On: SCA output, preset as second radio channel. The
2ch
Off: AUX output can be preset as SCA, or by SERL logic (the programming of a radio
control in the RADIO 2CH menu allows for the pedestrian passage opening).
An incorrect setting of these parameters may result in a danger.
Comply with regulations in force!
LOGICS (LOG)
FUNCTION
* WARNING:
logic should be OFF.
SERL
0-99-(50%)
0-25-(0)
MEMO
DEFAULT
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(ON)
(OFF)
15

Publicité

loading

Ce manuel est également adapté pour:

Cp.gliss2000.o.mcMatrix