POMPE DE SPA
3. INSTALLATION
▪ Pumps must the level installment, Dimensions and position of the pump for supporting and fixing the pump within this
space (Diagram.2).
▪ Pump must be fixed by screw on the tub shelf, and fixed with silent block to lower the noise and libration. Sticking and
enlacing is forbidden.
▪ The pump will be getting hot in operating , to speed up cooling, the minimum distance between the motor of the pump
and the surrounding structure should not be less then 20mm.
▪ The suction, pipe of the pump should be as short as possible.
▪ The rating Label must be visible after installation.
▪ Parts containing live parts, except parts supplied with safety extra low voltage<12V, must be inaccessible to a person in
the bath.
▪ Class I appliances must be permanently connected to fixed wiring. Part including electrical components except remote
control devices must be located or fixed so that they cannot into bath.
4. PIPE ASSEMBLY
▪ The maximum inlet water pressure ≤ 0.15MPa.
▪ The suction pipes should have a diameter equal to or larger than of the discharge pipes. It can avoid the loss of the head
and improve the efficiency.
▪ The suction and discharge pipes should not rest above the pump in any case.
▪ Seal all the connectors and unions well. Avoid any dripping on the motor, which would unfailingly damage it.
▪ Should be use the new hose module which supplements along with the bathtub, the old hose module cannot be reused.
5. ELECTRICAL CONNECTION
▪ The electrical installation should have a multiple separation system with contacts opening at least 3mm.
▪ For continued protection against possible electric shock this unit is to be mounted to the base in accordance with the
installation instructions.
1) The protection of the system should be based on a residual current device (RCD) with a rated tripping current not
exceeding 30mA.
The supply cable should comply with EMC standards.
2) Single-phase motors have built-in thermal protection.
▪ The electric connection must be carried out by qualified staff following strictly the «EN60335-2-60» standard.
▪ Be sure that the earth cable connection is correctly made.
▪ Wires serving as equipotential bonding conductors shall have a cross sectional area between 2.5 mm2 and 6 mm2 and
shall be equipped with the terminal suitable receptacle.
6. CONTROL PRIOR TO INITIAL START-UP
▪ Verify that the pump shaft turns freely.
▪ Check that the mains voltage and frequency are according to the name plate.
▪ The hydro massage assembly should be equipped with a system to prevent the pump from starting up if a minimum water
level is not present.
▪ Check the rotating direction of the motor, which should concur with that indicated on the fan cover.
▪ If the motor does not start up, try to locate the problem in the table of most common faults and their possible solutions
that is provided further on.
▪ THE PUMP SHOULD NEVER OPERATE DRY.