Connecteurs en ligne, valours nominales - 600 v, jusqu'a 690 a de courant continu, calibres de cable - de 250 a 750 mcm

Publicité

Liens rapides

WARNINGS AND CAUTIONS
TO AVOID FIRE, SHOCK OR DEATH, TURN OFF POWER at circuit breaker or fuse and test
that the power is off before wiring or disconnecting In-Line Connectors in use!!!
To be installed and/or used in accordance with electrical codes and regulations.
If you are not sure about any part of these instructions, consult an electrician.
Features
• Intermateable and compatible with competitive same nose cam-type products - can be retrofitted
to existing locations and power distribution systems
• Shatter and crack proof - high durometer rubber sleeve
• Color coded insulating sleeves - fast and easy phase identification
• Cam adjustment screw - Precision tension adjustments positively increase and decrease cam tension
• Fast connect/disconnect - twist and pull double cam/guide boss design.
• High conductivity - positive, vibration proof connection provided by double cam design
• Wide variety of applications - usable with a wide range of cable sizes and amperage ratings
NOTES: Use Ampacity Table to ensure proper selection of cable and to select proper Burndy die part number for crimp tube applications.
The captivating screw hole in the contact is in line with the flat part of the cam for the male contacts, and in line with the guide boss for the female contacts.
Use Leviton Silicone Spray Lube or cable pulling compound and a Com-a-Long tool to assist assembly of contact and sleeve if necessary.
Detachable In-Line Connectors (with set screws)
Prepare cable.
Step 1
Strip
2-1/4"
Cable
Conductor
Connect contact.
Step 2
WARNING
DO NOT over tighten set screws to avoid stripping
of threads, or losing set screw inside of contact.
Torque to 10 ft-lbs.
NOTE: Tighten set screw #1 first.
Screw #1 #2
Insert
Male Contact
Install sleeve.
Step 3
Male contact
(shown)
NOTE: Use Leviton spray lube and com-a-long tool if necessary.
Optional - Install shrink tube.
Step 4
A )
Align, push together and twist.
Male Connector
AMPACITY TABLE
Ampacity
Cable
Bore Size -
Size
60°C
75°C
90°C
Crimped (in).
(MCM)
Cable
Cable
Cable
340
405
455
250
375
445
505
300
420
505
570
350
455
545
615
400
515
620
690
500
575
690
-
600
630
-
-
700
655
-
-
750
© 2017 Leviton Mfg. Co., Inc.
17, 19, 22, 23 Series In-Line Connectors
INSTALLATION AND OPERATION INSTRUCTIONS
Copper Shim
Wrap
CORRECT
Set screw
Contact
Conductor
Screw #2
#1
Female Contact
Captivating screw
Align
(torque 16 in-lbs)
Sleeve
Shrink tube
Connect
Female Connector
Burndy Die
NOTE:
Part No.
Consult crimp tool
manufacturer if other
0.83
U29RT
than Burndy.
0.83
U30RT
0.83
U31RT
0.98
U32RT
0.98
U34RT
1.17
U36RT
1.17
U39RT
1.17
U39RT
Rated: 600V, up to 690A continuous current
Cable Size: 250 - 750 MCM
WARNINGS AND CAUTIONS
Use copper cable only. DO NOT exceed 690A of cable/contact assembly.
Acceptable cable types include: DLO, W & P.
Female contacts for taper nose and ball nose devices are not interchangeable.
Taper nose assemblies will not mate properly with ball nose assemblies.
Tools and Materials Required
• Razor Cutting Blade
• Flat Head Screw Driver
• Allen Wrench
• Wire Cutter
• Burndy PAT750 Crimp Tool
and Die (for Non-Detachable)
In-Line Connectors)
Non-Detachable In-Line Connectors (with crimp tube)
Prepare cable.
Step 1
Connect contact.
INCORRECT
Step 2
Insert
Insert
Install sleeve.
Step 3
Latching band
NOTE: Ensure contact is fully seated and
locked in place before use.
NOTE: Use Leviton spray lube and com-a-long tool if necessary.
B )
Heat
* NOTE: For 22 and 23 Series Connectors, depress button on sleeve, untwist and pull apart.
• Com-a-Long Tool (optional)
• Shrink Tube (optional)
• Leviton Spray Lube -
Cat No. C0001 (optional)
Strip
2-1/4"
Cable
Conductor
Male Contact
Crimp
(use Burndy PAT750 tool and die)
NOTE: Consult Ampacity Table for appropriate Burndy die part number.
Guide pin (male contact shown)
Align
C )
Disconnect
* Depress button
Male Connector
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in
writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality Assurance
Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at
1-800-405-5320.
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product
at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper
use for two years from the purchase date. Leviton's only obligation is to correct such defects by repair or
replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty
excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty
is void if this product is installed improperly or in an improper environment, overloaded, misused, opened,
abused, or altered in any manner, or is not used under normal operating conditions or not in accordance
with any labels or instructions. There are no other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if any implied warranty is required by the
applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness
for a particular purpose, is limited to two years. Leviton is not liable for incidental, indirect, special, or
consequential damages, including without limitation, damage to, or loss of use of, any equipment,
lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided
herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com
PK-A3186-10-02-0A
English
Contents
Detachable Connectors
• Copper Shim
• Hex Head Socket Set Screws (2)
• Insulated Head Contact Captivating Screw
• Contact
• Sleeve
Non-Detachable Connectors
• Contact
• Sleeve
Female Contact
Insert
Slot on inside of sleeve
(under arrow)
Sleeve
Female Connector

Publicité

loading

Sommaire des Matières pour Leviton 17 Serie

  • Page 1 The captivating screw hole in the contact is in line with the flat part of the cam for the male contacts, and in line with the guide boss for the female contacts. • Sleeve Use Leviton Silicone Spray Lube or cable pulling compound and a Com-a-Long tool to assist assembly of contact and sleeve if necessary. Detachable In-Line Connectors (with set screws) Non-Detachable In-Line Connectors (with crimp tube) Prepare cable.
  • Page 2 El orificio del tornillo cautivo en el contacto se alinea con la parte plana de la leva respecto de los contactos machos y se alinea con brida guía respecto a los contactos hembra. Use el Lubricante Leviton en Aerosol a base de Silicona o compuesto para extracción de cables y una mordaza tensadora para ensamblar el contacto y el casquillo, según sea necesario.

Ce manuel est également adapté pour:

19 serie22 serie23 serie19d24-e17d24-h22l22-o ... Afficher tout