Assembly; In The Bathtub; Cleaning | Maintenance; Cleaning & Maintenance - Drive BENNY Mode D'emploi

Masquer les pouces Voir aussi pour BENNY:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Assembly

Handle
If necessary, remove both plastic screws from the handle.
Insert these from below into the openings provided in the
bath board. The white cover parts for the holes are then
pushed upwards and fall out. Insert handle from above –
facing inwards (pic. 2) – into the openings provided on
the bath board and tighten the fixing screws underneath
(such as with a coin) to secure the handle (pic. 3).
2
Stop bolts
If necessary, remove the plastic screws on top from the
stop bolts. Insert a screw from above downwards into
each slot on the bath board, position rubber rings against
the screw from underneath (pic. 4+5) and gently screw
on the stop bolts from underneath (pic. 6).
4
5
Do not tighten the stop bolts yet so that they can be
adjusted within the slot to the width of the tub afterwards.

In the bathtub

Place bath board across the tub on the edge of the tub.
The handle must face the wall. The bath board must be
positioned properly on the right and left. Push the stop
bolts in each slot all the way outwards to the edge of the
tub so that the board is secured in place.
Now tighten the screws (pic. 7).
7
Drive Medical GmbH & Co. KG | As per: 23.04.2020 | Errors and alterations excepted
3
6

Cleaning | Maintenance

• Clean regularly with a moist cloth!
• Do not use any aggressive cleaning agents!
• Do not use abrasive cleaners!
• Do not use any high-dose chlorine and vinegar-based
cleaners!
• To disinfect, a spray disinfectant can be used such as
Descosept AF or Bacillol AF.
• Check the screws regularly and tighten, if necessary.
• The product should not be exposed to temperatures
above 60° C for long periods of time (for example, use
in a sauna, etc.).
• In the event of defects, contact your specialist dealer
from whom you purchased this product.

Technical data

Product
Article number
HMV (medical
04.40.02.0017
aids register) no
Technical data
Overall width
Overall length
Adjustment range
(interior width of tub)
Total weight
Max. load
Product
Benny XL 68 cm
Article number
Technical data
Overall width
Overall length
Adjustment range
(interior width of tub)
Total weight
Max. load
Instructions for use BENNY / BENNY XL
EN
Benny 68 cm
Benny 73 cm
550100100
550100200
04.40.02.0016
35 cm
35 cm
68 cm
73 cm
40 - 63 cm
43 - 68 cm
2.1 kg
2.6 kg
150 kg
150 kg
Benny XL 73 cm
550100300
550100400
35 cm
35 cm
68 cm
73 cm
40 - 63 cm
43 - 68 cm
2.2 kg
2.7 kg
225 kg
210 kg
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Benny xl

Table des Matières