2/INSTALLING YOUR APPLIANCE

BEFORE HOOK-UP

Warning:
Ensure that your appliance has not
suffered any damage during transport
(deformed seal or door, etc...). If you see
any kind of damage, before doing anything
else, contact your retailer.
In order to easily locate the reference infor-
mation for your appliance, we recommend
that you note these data on the "After-
Sales Service Department and Customer
Relations" page.

ELECTRICAL CONNECTION

Ensure that:
- The electrical installation has sufficient
voltage.
- The electrical wires are in good condition.
- The diameter of the wires complies with
the installation requirements.
- Your electrical installation is equipped with
16-ampere thermal-sensitive protection.
In case of doubt, consult your electrician-
installer.
The electrical connections are made before
the appliance is installed in its housing.
Electrical safety must be provided by a cor-
rect build-in. During installation and main-
tenance operations, the appliance must be
unplugged from the electrical grid; fuses
must be cut off or removed.
The oven must be connected with a power
cable (standardized) with three 1.5 mm
conductors (1 ph + 1 N + ground) that must
be connected to a monophase 220-240 V
network via a CEI 60083 standardised recep-
tacle (1 ph + 1 N + ground lead) or in accor-
dance with installation rules. The safety
wire (green-yellow) is connected to the
appliance's terminal
connected
to
the electrical set-up.
and must be
the
ground lead of
In the case of connections with an electric
receptacle, it must remain accessible after
installation of the appliance.
The oven's neutral conductor (blue wire)
must be connected to the network's neutral
conductor.
In your electrical installation, allow for a
user-accessible device that must be able
to separate the appliance from the main
power supply and whose contact opening is
at least 3 mm above all the terminals.
If the power cable is damaged, it should be
replaced by the manufacturer, its after-sales
service department or by a qualified person
to avoid danger.
Warning:
We cannot be held responsible for
any accident resulting from an inexistent,
defective or incorrect ground lead.
If the oven malfunctions in any way, unplug
the appliance or remove the fuse corres-
ponding to the sector there the oven is
hooked up.