RATINGS AND PERFORMANCE
Power, total (Kw)
Power, first stage (Kw)
Net capacity (BTU/h)
Heating temperature rise range (F)
ELECTRICAL SYSTEM
Volts - Hertz - Phase
Electrical element #1 (Kw)
Electrical element #2 (Kw)
Electrical element #3 (Kw)
Electrical element #4 (Kw)
Electrical element #5 (Kw)
Electrical element #6 (Kw)
Blower motor Consumption (Amp. Max.)
Heating Elements Consumption (Amp)
Total Consumption (Amp)
2
Circuit Amperage
(wire sizing)
Maximum size circuit breaker (Amp)
BLOWER DATA (factory adjusted to a staic pressure of 0.5" W.C.)
Blower speed at 0.50" W.C. static pressure
Blower speed at 0.20" W.C. static pressure
Motor (HP) / number of speeds
Nominal blower size (diam. X width)
GENERAL INFORMATION
Overall dimensions (width x depth x height)
Supply
Return
Filter quantity and size
Shipping weight
Maximum cooling capacity
1) Select a blower speed that will generate the specified temperature rise
2) Calculated on the basis of Norm C22.2 Nr. 236
Blower Speed
LOW
MED-LOW
MED-HIGH
1090
HIGH
1285
The airflow values are expressed in cubic feet per minute (CFM'), rounded to 5 CFM more or less.
These readings were taken with the air filter installed.
Blower Speed
LOW
1035
MED-LOW
1315
MED-HIGH
1715
HIGH
1935
The airflow values are expressed in cubic feet per minute (CFM'), rounded to 5 CFM more or less.
These readings were taken with the air filter installed.

Table 3 : Technical specifications

10
5
34 120
1
40-50
5
5
6
41
47
59
2
60
LOW
LOW

Table 4 : Airflow (CFM) - SUPREME with 1/3HP motor

0.1
0.2
715
700
935
900
1050
1250

Table 5 : Airlfow (CFM) - SUPREME with 1HP motor

0.1
0.2
1030
1300
1650
1900
FEMxx-M2401AM-B
15
18
20
10
9
10
51 180
61 420
68 240
45-60
50-75
55-75
3 wires 120 / 240 - 60 - 1
5
4
5
5
5
4
5
6
6
61
74
82
67
80
88
84
100
112
90
100
125
MED-LOW MED-LOW MED-HIGH MED-HIGH MED-LOW MED-LOW MED-LOW
MED-LOW MED-LOW MED-LOW MED-HIGH MED-LOW MED-LOW MED-LOW
1/3 HP / 4 speeds
10 x 8
20" x 20" x 36.5"
3 tons
Static Pressure
0.3
0.4
690
675
870
835
1010
970
1220
1185
Static Pressure
0.3
0.4
1030
1025
1285
1270
1590
1525
1870
1835
10

FEMxx-M2401BM-B

23
20
13
10
78 480
68 240
60-80
55-75
5
4
5
5
5
5
5
4
5
5
5
5
5
6
6
13
94
82
100
95
125
119
125
125
15" x 18"
19" x 19"
(1) 20" x 20"
48 Kg / 105 lbs
0.5
0.6
660
650
800
770
930
890
1150
1120
0.5
0.6
1020
1020
1255
1240
1460
1400
1800
1770
23
27
13
15
78 480
92 130
60-80
60-80
4
5
5
5
4
5
5
4
5
4
4
13
13
94
111
107
124
134
155
150
175
1 HP / 4 speeds
12 x 10
5 tons
0.7
635
735
850
1085
0.7
1015
1225
1335
1735

Publicité