Function Default Settings
Function N. Description
F01
Automatic setting using dP (1) or manual (0)
F02
Solenoid value activation time
F03
Washing pause time between solenoid valves in normal cycle
F04
Number of outputs
F05
Output voltage 24 Vdc, 24 Vac, 115 Vac, 230 Vac
F06
Manual solenoid valve activation
F07
Zero dP threshold
F08
Cycle start dP threshold
F09
Cycle stop dP threshold
F10
Max. dP level
F11
Fan mode: 0 from contact, 1 from dP
F12
Fan dP threshold (if F11=1). If < fan off
F13
Number if cycles after fan stop
F14
Pause time between solenoid valves in cycle with fan off
F15
Maintenance frequency in 10h (1=10h, 100=1000h)
F16
Maintenance deadline alarm on (1) or off (0)
F17
Maintenance hour counter reset: set 1 and confirm to reset the maintenance hour counter
F18
Precoating on (1) or off (0)
F19
Precoating dP threshold (if F18=1)
F20
Enabling Min. dP Alarm function
F21
Min. dP Alarm threshold (Brocken Sleeve / Cartridge)
Cleaning Cycle Forced (only available in operating mode F01=2)
F22
Set if it handled in minutes or if in hours
F23
Setting the interval time in relation to the choice of F22
F26
Exclusion of valve in short circuit
32
Set Value
1
0.20 sec
20 sec
1
115 Vac
1
0 inch WC
3.2 inch WC
1.6 inch WC
12 inch WC
1
0.4 inch WC
1
10 sec
100
0
0
0
8 inch WC
0
0.8 inch WC
0
240
0