Generator Compatibility; Installation; Transceiver Installation; Generator Side Transceiver Installation Instructions - Air-Cooled Generators - Generac 006664-0 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation

GENERATOR COMPATIBILITY

• This unit can be installed on all 2008 and later air-cooled home standby units with an LCD
display and all 2010 and later liquid-cooled gaseous fuel standby units. The unit can also be
used on 2013 and later Evolution controlled liquid-cooled diesel fuel standby units.
• For liquid-cooled units, an additional adapter harness is required (model 006665-0).
• Maximum ambient temperature rating: 122 °F / 50 °C.

TRANSCEIVER INSTALLATION

GENERATOR SIDE TRANSCEIVER INSTALLATION INSTRUCTIONS - AIR-COOLED
GENERATORS
The following steps illustrate how to mount the generator side transceiver to an air-cooled generator.
For liquid-cooled generator applications, an adaptor kit is required and comes with additional
instructions.
The generator battery will be disconnected and reconnected during the installation
process which may result in an "Inspect Battery" warning being displayed on the generator
controller. This is normal and is no cause for concern; simply clear the warning from the
generator controller following the operating instructions for the generator controller. The
time and date will also need to be reset once the starting battery is reconnected.
1.
Remove the T1 fuse from the transfer switch.
2.
Unlock both locks and open the top lid of the generator.
3.
Set the generator to the OFF mode.
4.
Remove the 7.5 Amp control panel fuse.
5.
Remove the front access panel from the enclosure.
6.
Disconnect the negative (-) black battery cable. Then, disconnect the positive red (+) cable.
7.
If applicable, turn OFF the main breaker in your home's utility breaker electrical panel. This is
necessary if installation is being performed after the generator has been connected to utility
power.
There are different controller configurations for various model years. Follow the next steps
related to your generator depending on the model year.
Transceiver Installation - 2008 - 2012 with LCD Display
1.
Locate the mounting feature and cover plate on the back of the generator. Remove the cover
plate, then position transceiver on the back of the generator ensuring the gasket provides
sealing.
6
NOTE:
NOTE: