3 Identification data

The TWRC1 box rack has two labels that comply with CE marking.
The first label contains:
Model identification code (Extended 3/9 Bar-code)
Power supply voltage (Volt)
Consumption (Watt)
The second label shows the model serial number (Extended 3/9 Bar-code)
Before commencing installation, make sure the transmitter's power supply specifications correspond to those
required. The use of inappropriate equipment may subject personnel and the system itself to serious safety hazards.

4 Installation

Installation must only be carried out by skilled, authorised personnel.

4.1 Opening the package

If the package is not obviously damaged (due to dropping or abnormal scrapes and scratches), check the
material contained in it against the list given in the Package contents section of the Introduction.
All the packaging materials are completely recyclable. The installer technician will be responsible for disposing of them by
recycling or according to the legislation in force in the country of use.

4.2 Checking the markings

Before proceeding further with installation, check the identification plates to make sure the supplied
material corresponds with the required specifications, as described in the Identification data section.
Never, under any circumstances, make any changes or connections that are not described in this manual: the
use of inappropriate appliances may expose personnel and the system itself to serious safety hazards.

4.3 Connections

Insert the TWRR1 receivers in their respective slots, assembling the board guides (up to a maximum of 14
receivers per box)
Assemble the blind front panels in the positions that are not occupied by receivers
Connect the coaxial cables coming from the monitors to the BNC connectors on the back panel
Connect the twisted pairs coming from the transmitters to the terminals indicated by A and B the back panel
Insert the power supply jack
To adjust the receivers, see the corresponding user's manual
The box rack can also be powered at 24VAC using the appropriate terminal, if the older model of receiver that
cannot be powered at 12VDC is being used. In this case it is necessary to obtain a 24 Vac - 40VA power supply