Télécharger Imprimer la page
Reelcraft L4000 Serie Consignes D'utilisation

Reelcraft L4000 Serie Consignes D'utilisation

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Operating Instructions
Condensed Version (Cord/Cable)
Read these instructions carefully before attempting to install, operate or maintain this
product. Only qualified persons should install this product. Failure to comply with
instructions may result in personal injury and/or property damage. Every attempt is made
to ensure the accuracy and completion of these instructions; however, manufacturer is not
responsible for ommissions. To obtain the complete version of Reelcraft's service manuals,
please visit www.reelcraft.com or call Customer Service during business hours. For Technical
Bulletins and support, please visit www.reelcraft.com.
Safety
1. Ensure that power supply voltage does not
exceed maximum voltage rating of reel. Also,
ensure that reel is properly installed before
connecting to power supply.
2. All cord reels with GFCI receptacles must be
hard wired to ensure proper function.
3. Check for frayed/broken wires before each
use.
4. Do not exeed maximum installation height
of 16 ft unless specified.
5. A high tension spring assembly is contained
within the reel. Exercise extreme
caution.
6. Remove all spring tension and electric
power before beginning any disassembly
process.
7. If an electrical malfunction should occur,
remove power from reel immediately.
8. Ensure that reel, electrical cord, and
equipment being serviced are properly
grounded. Use an ohmmeter to check ground
continuity.
9. Reels that include explosion-proof
fluorescent hand lamps are not
explosion-proof themselves.
10. The Ground Fault Circuit Interrupter
Receptacle is designed to protect people
from line-to-ground shock hazards. The
GCFI does not protect against short circuits
or overloads. This is the function of the fuse
or circuit breaker. Test monthly.
11. Pull electrical cord from reel by grasping
the electrical cord itself, not the work device.
12. If reel ceases to unwind or rewind, remove
electrical power immediately. Do not jerk
excessively on electrical cable!
13. Treat and respect the cord reel as any
other piece of machinery, observing all
common safety practices.
Installation
Ensure that only a qualified electrician
installs/services this equipment. Observe
applicable NEC, OSHA, and local electrical codes
when installing this equipment. Installation of
GFCI cord reels should be performed by a
Page 1
Form #1213-109 REVISED: 8/09
qualified and licensed professional in
accordance with local building codes and
applicable NEC standards.
Mounting & Guide Arm Adjustment
The cord reel is equipped for universal mounting
so that it can be mounted on a structurally sound
floor, wall or ceiling; whichever provides
maximum performance. The guide arm must be
rotated to a position that allows the cord to feed
through the roller brackets with minimal
bending. Replace the fasteners. Where applica-
ble, the U-Bolt must be placed in the proper
location when rotating the guide arm, otherwise
the reel might "latch out" during use. Refer to
online manual for proper U-Bolt locations.
Lubrication
Cord reel spring and bearings are factory
lubricated and require no further lubrication.
Install/Replace the Electrical Cord
CAUTION: Exercise extreme caution when
adding or removing spring tension. Ensure reel
base is fastened down prior to adjusting
tension. Do not move spool while tightening
cord or latch will disengage.
1. Wind spool flange required number of turns
to achieve proper tension (Refer to online
Tech Bulletin). Do not over-tighten.
2. Engage cord latching mechanism.
Remove access cover.
3. Strip 6" (L4000), 8" (L7000) or 11"
(L5000) of output electrical cord outer jacket.
4. Route cord through U-Bolt*, cutout in
spool, then through strain relief (90° elbow).
Tighten U-Bolt* and strain relief (90° elbow)
as required. *Where applicable; not all
models contain a U-bolt.
5 Using wire nuts, connect output electrical
cord wires to collector assembly brush
wires. Connect ground wire of output
electrical cable to ground lug.
6. Check for ground faults using an ohmmeter.
7. Install access cover. Carefully release latch
and firmly hold the cord while winding it
onto reel. Install cord bumper stop at desired
position.
Rely on Reelcraft
Industrial s Automotive s Construction s Aviation s Fuel Delivery s Much more
2842 East Business Hwy 30, Columbia City, IN 46725 USA
s
Better by Design
TM
TM
Reelcraft Industries, Inc.
Toll-free: 1-800-444-3134 or 260-248-8188
Toll-free fax: 1-800-444-4587 or 260-248-2605
reelcraft@reelcraft.com www.reelcraft.com
Heavy Duty Cord Reels
Series L4000
Series L5000
Series L7000
Refer to page 4 for dimensional drawings.
Series L4000
L 4545 123 7
Series L4000
Note: The Ground Fault Circuit
L 4050 163 3
Interrupter does not protect against
short circuits or overloads.
Series L4000
Series L4000
L 4035 162 2
L 4050 163 X
Series L5000
L 5700
Series L5000
L 5245 A 163 6X
UL LISTED
Note: Reel is not explosion proof.
Spring Tension Adjustments
To adjust spring tension, add or remove wraps
of cord from the spool, one wrap at a time, until
desired tension is obtained (refer to caution
above and online Tech Bulletin). Cord
latching mechanism can be removed for constant
tension applications.
Repairs
Extensive repairs should be performed only by
the factory service center to avoid damage which
may cause serious injury or void your warranty.
CAUTION: Remove all spring tension and
electrical power before disassembly process.
www.reelcraft.com
www.reelcraft.com

Publicité

loading

Sommaire des Matières pour Reelcraft L4000 Serie

  • Page 1 Heavy Duty Cord Reels responsible for ommissions. To obtain the complete version of Reelcraft’s service manuals, please visit www.reelcraft.com or call Customer Service during business hours. For Technical Bulletins and support, please visit www.reelcraft.com.
  • Page 2 Para obtener la versión completa de los manuales de uso de cable eléctrico servicio de Reelcraft, visite www.reelcraft.com o llame a Servicio al Cliente en horario de Serie L4000 Serie L5000 oficina.
  • Page 3 Pour Dérouleurs de cordon industriels obtenir la version complète des manuels de service de Reelcraft, veuillez visiter le site www.reelcraft.com, ou appeler notre assistance à la clientèle pendant les heures ouvrées.
  • Page 4 Reelcraft ofrece ahora una garantía limitada por Reelcraft offre désormais une garantie limitée de Reelcraft now offers a two year limited warranty on most products. Failure to install or maintain dos años en la mayoría de sus productos. Si los deux ans sur la plupart de ses produits.

Ce manuel est également adapté pour:

L5000 serieL7000 serieL 4050 163 3L 4545 123 7L 4035 162 2L 4050 163 x ... Afficher tout