INSTALLATION
For field wiring information, please refer to the instructions attached to inside of front cover.
• Make sure that all unused taps (leads) are separately insulated.
• Use the following tables as a guide to determine the correct wire size.
• The voltage at lamp terminals after installation should be 12 ± 0.3 VAC.
• Voltages above 12.3 VAC at the light may cause the internal safety fuse of the transformer to
switch off and on. To prevent this from happening follow chart below for correct voltage and
wire gauge selection.
1. Select power source by combining Bulb wattage.
2. Determine length of cable run(s).
3. Determine wire gauge needed to deliver necessary power.
4. Connect cable to output tap of transformer given in table.
Transformer Cable - Voltage Selection Chart
Length of Cable
10 ft
13 V
25 ft
13 V
50 ft
14 V
75 ft
100 ft
125 ft
150 ft
175 ft
200 ft
250 ft
#16*
Wire Gauge (AWG)
* Minimum Gauge Cable
**Blank fields indicate conditions not suited for wiring
• Use only CSA or UL certified low-voltage cable.
• Low voltage cable shall be buried a maximum 6
inches (15.2 cm) in order to connect to the main low
voltage cable.
Warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased or (b) completing
a warranty claim online at www.intermatic.com. This warranty is made by: Intermatic Incorporated, 1950 Innovation Way, Suite
300, Libertyville, IL 60048.
For additional product or warranty information go to: http://www.Intermatic.com or call 815-675-7000.
Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material contained
herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.
INTERMATIC INCORPORATED,
Pool/Spa Underwater Lighting Application
100 W Transformer
12 V
12 V
12 V
12 V
13 V
12 V
12 V
12 V
13 V
13 V
12 V
12 V
14 V
13 V
13 V
12 V
13 V
13 V
13 V
14 V
13 V
13 V
14 V
13 V
13 V
14 V
14 V
13 V
14 V
13 V
14 V
13 V
#14
#12
#10
#8
LANDSCAPE LIGHTING APPLICATIONS
http://www.intermatic.com
Length of Cable
12 V
12 V
12 V
12 V
12 V
12 V
13 V
13 V
13 V
13 V
#6
Wire Gauge (AWG)
* Minimum Gauge Cable
**Blank fields indicate conditions not suited for wiring
Transformer Wattage (W)
LIMITED WARRANTY
2
Transformer Cable - Voltage Selection Chart
300 W Transformer
10 ft
12 V
12 V
25 ft
13 V
13 V
50 ft
13 V
13 V
75 ft
14 V
100 ft
14 V
125 ft
150 ft
175 ft
200 ft
250 ft
#12*
#10
Minimum Gauge AWG
300
100
LIBERTYVILLE, IL 60048
12 V
12 V
12 V
12 V
13 V
13 V
13 V
13 V
14 V
13 V
14 V
13 V
14 V
14 V
14 V
14 V
14 V
#8
#6