IDEAL 33-772 Mode D'emploi page 6

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Standby - Cable Test
1. When in RJ-45 mode,
2. Connect cable to the Tester (see following
screens for more demonstrations) Note:
When there is no remote connected,
shield and no shield will not appear.
Test in Progress - Cable Test
1. Test repeats every 3 seconds (max.);
when test is in progress, "Test" appears
on the first line, when test is completed,
test result "Pass" or "Fail" appears
replacing "Test";
2. Wire Map shows correct wiring when ID # indicates the particular Remote
which is in use;
3. The last line shows the length of cable being tested;
4. Beeper icon appears only when Beeper is OFF; low battery icon appears
only when the battery is below 5.5V
Test results of an all normal shielded cable with TIA-568-B wiring:
1. "Pass" appears on the first line;
2. Wire Map shows correct wiring when
ID # indicates the particular Remote
which is in use;
3. The last line shows the length of cable
being tested;
Test results of a shielded 4-pair data cable, T-568-B wiring, but a
cross-over cable
1. "Pass" appears on the first line;
2. Third row of screen displays pin numbers
where cross-over was detected;
3. "RJ-45 X-OVER" displayed on the
last line.
Test result of an unshielded 4-pair data cable, standard T-568-B
wiring, No Remote Unit is connected and with 1,3 Shorted, screen
displays as:
1. When test is in progress "Test" blinks;
when test is completed "Test" goes off
and is replaced by "Fail".
2. Third row of screen displays
"No Remote?";
3. Error messages "Short 1-3" displayed
on the last line.
Test
RJ45
12 36 45 78
Pass Pre-Test
15.5 ft
Cycling in sequential order 1-2, 3-6, 4-5,
7-8
Test
RJ45
12345678
12345678
11.5m
Test
RJ45
12345678
12345678
11.5m
Pass
RJ45
12345678
36145278
RJ45 X-OVER
Fail
No Remote?
Short
6
No Shield
ID1
Shielded
ID1
Shielded
ID 1
13