3. Specifications
3) ZM1000-ARX Electrical & Physical Specifications
AC Input Range
Frequency
AC Input Current
PFC Type
Power Factor Correction
Inrush Current Limit
(@ Cold Start at 25℃)
Efficiency
+3.3VDC
DC Output Voltage
Regulation
+12VDC
+3.3VDC
DC Output Ripple
& Noise
+12VDC
4) ZM1200-ARX Electrical & Physical Specifications
AC Input Range
Frequency
AC Input Current
PFC Type
Power Factor Correction
Inrush Current Limit
(@ Cold Start at 25℃)
Efficiency
+3.3VDC
DC Output Voltage
Regulation
+3.3VDC
DC Output Ripple
& Noise
3
Voltage
100~240VAC ±10%
50Hz ~ 60㎐ ±3
100VAC
12-6A
240VAC
Active PFC
Max 99%
100VAC
Max 50A
240VAC
Max 94% @ 230VAC, Typical load
Vout
Regulation Range
+3.14 ~ +3.47V
±5%
+4.75 ~ +5.25V
+5VDC
±5%
+11.4 ~ +12.6V
±5%
-12VDC
-10.8 ~ -13.0V
±10%
+5VSB
+4.75 ~ +5.25V
±5%
Vout
Standard Range
50mV
+5VDC
50mV
120mV
-12VDC
120mV
+5VSB
50mV
Voltage
115-240VAC ±10%
50Hz ~ 60㎐ ±3
12.6-6A(EU) /
115VAC
12-6A(North America)
240VAC
Active PFC
Max 99%
115VAC
Max 50A
240VAC
Max 94% @ 230VAC, Typical load
Vout
Regulation Range
+3.14 ~ +3.47V
±5%
+4.75 ~ +5.25V
+5VDC
±5%
+11.4 ~ +12.6V
+12VDC
±5%
-12VDC
-10.8 ~ -13.0V
±10%
+5VSB
+4.75 ~ +5.25V
±5%
Vout
Standard Range
50mV
+5VDC
50mV
+12VDC
120mV
-12VDC
120mV
+5VSB
50mV
Output Load Rating
Vout
I
I
min
max
+3.3V
0.1A
25A
0.2A
+5V
22A
0.2A
83A
+12V
-12V
0.0A
0.3A
+5VSB
0.0A
2.5A
Ambient Temperature
Operation
Storage
Ambient Humidity
At
Operation
Full
Storage
Load
Dimensions
180(D) x 150(W) x 86(H)mm
Weight
Protection Functions
Over-Current Protection (OCP)
Over-Voltage Protection (OVP)
At
Under-Voltage Protection (UVP)
Full
Load
Short-Circuit Protection (SCP)
Over-Power Protection (OPP)
Over-Temperature Protection (OTP)
Output Load Rating
Vout
I
I
min
max
+3.3V
0.1A
25A
0.2A
+5V
22A
0.2A
+12V
100A
-12V
0.0A
0.3A
+5VSB
0.0A
2.5A
Ambient Temperature
Operation
Storage
Ambient Humidity
At
Operation
Full
Storage
Load
Dimensions
180(D) x 150(W) x 86(H)mm
Weight
Protection Functions
Over-Current Protection (OCP)
Over-Voltage Protection (OVP)
At
Under-Voltage Protection (UVP)
Full
Load
Short-Circuit Protection (SCP)
Over-Power Protection (OPP)
Over-Temperature Protection (OTP)
English
Combined
Power
I
peak
120W
996W
1000W
3.6W
12.5W
0 ~ +40℃
-20 ~ +70℃
5% ~ 95% RH
5% ~ 95% RH
3.05kg
Combined
Power
I
peak
120W
1200W
1200W
3.6W
12.5W
0 ~ +40℃
-20 ~ +70℃
5% ~ 95% RH
5% ~ 95% RH
3.1kg