4. Slide the network cable through the slit on the gasket to attach the gasket to the network
cable.
5. Route the network cable through the cable gland.
6. Press the gasket into the cable gland and screw the cap on firmly.
Notes:
• Using any other than the provided cable gland may cause water to seep in and damage the product.
Cables must have a diameter of 4.0 mm - 5.5 mm.
• Due to local regulations or the environmental and electrical conditions in which the product is to be
used, a shielded network cable (STP) may be appropriate or required. Any network cables that are
routed in outdoor environments or similar shall be shielded (STP) and intended for their specific use.
Make sure the network switch is properly grounded. See Electromagnetic Compatibility (EMC) for
regulatory requirements.
Attach the camera to the wall bracket
1. Place the camera with the bottom cover on the bracket and tighten the bracket adapter screws.
2. Replace the cable cover and tighten the screws.
3. Connect the camera to the network.
Note: If more than one cable is used, for external input/output devices for example, each cable must
be routed through a separate cable gland, see Route the network cable through the cable hole.
Bracket adapter
screw (4x)
Bracket adjustment screw
4. Loosen the bracket adjustment screw to aim the camera to the point of interest and focus the
camera if required. If the lens has been changed, the camera's image source has to be updated.
See Indoor/outdoor cameras, on page 8. See the Installation Guide provided with the camera for
information on how to access the video stream.
5. Attach the safety wire to the tab on the bottom cover.
6. Attach the top cover to the bottom cover. Make sure to tighten diagonally opposite bottom
cover screws a few turns at a time until all are tight. This will help ensure that the bottom cover
gasket is compressed evenly.
7. Loosen the sunshield adjustment screws and adjust the sunshield to the desired position.
Axis Thermal Camera Accessories and Spare Parts Installation Guide
Network cable (route through wall bracket)
Safety wire tab
Cable holes with cable glands
Bottom cover
Cable cover
Cable cover screw (2x)
Wall bracket