Technical And Legal Information - Culina UBHHH60BK Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Wiring
WARNING: THIS APPLIANCE MUST NOT BE EARTHED.
Mains Supply could be connected to the Mains Voltage by Direct Connection
EUR
N (Blue)
L (Brown)
Direct Connection
If the appliance is being connected directly to the mains an omnipolar circuit-
breaker must be installed with a minimum opening of 3mm between contacts.
The installer must ensure that the correct electrical connection has been made
and that it complies with wiring diagram.
The cable must not be bent or compressed.
Regularly check the power plug and power cord for damage. If the supply cord is
damaged, it must be replaced by a special cord or assembly available from the
manufacturer or its service agent.
All installation work must be carried out by a competent
person or qualified electrician.
Before connecting the mains supply ensure that the mains
voltage corresponds to the voltage on the rating plate.
N (Blue)
L (Brown)
Technical and legal
UK
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
FUSE ON
USE A 3AMP FUSE
information
GB
IE
15