2-
Electrical Wiring Diagram
Note:The swimming pool heater must be connected to the
earth rod.
Options for circuit breakers and wire specs
MODEL
Rated Current A
Breaker
Rated Residual Action
Current mA
Fuse
A
2
(mm
Power Cord
2
(mm
Signal cable
※ Above data is subject to modification without notice.
GP00
GP01
GP02
GP03
6
15
15
20
30
30
30
30
7
15
15
20
3×1.5
3×2.5
3×2.5
3×2.5
3×0.5
3×0.5
3×0.5
3×0.5
- 21 -
GP04
GP05
GP06
GP07
25
40
15
20
30
30
30
30
25
40
15
20
3×2.5
3×4
3×6
5×2.5
3×0.5
3×0.5
3×0.5
3×0.5