Battery Charging Safety; Grounding Of Electrical Equippment - Battery Charger; Grounding Instructions; Unpacking Instructions - NSS Enterprises Wrangler 2012 AB Manuel De L'opérateur

Récureuse/sécheuse de planchers automatique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Battery Charging Safety

WARNING:
wall outlet before disconnecting batteries from ma-
chine to prevent arcing or machine damage.
ALWAYS charge the batteries with the Recovery Tank
open.
• ALWAYS read instructions carefully.
• ALWAYS use the NSS supplied charger with proper
voltage rating.
• ALWAYS plug the charger into an earthed socket
outlet.
• NEVER operate charger if the AC supply cord is
damaged, or if the charger has been damaged in
any way.
• NEVER charge a frozen battery.
• For flooded lead acid batteries (does not apply to
sealed maintenance free batteries):
• ALWAYS check to ensure the battery water level
covers the battery plates before charging.
• ALWAYS check water level after charging and
add distilled water if necessary to bring level to
the bottom of the fill hole.
• NEVER overfill batteries as battery and machine
damage may result.
• ALWAYS wipe any acid from the top of batteries
using a soap solution.
• ALWAYS reattach caps to batteries. Do not
charge with caps loose or removed.
• ONLY use distilled water.
GROUNDING OF ELECTRICAL
EQUIPPMENT - BATTERY CHARGER
WARNING:
equipment–grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or
service person if you are in doubt as to whether the
outlet is properly grounded. Do not modify the plug
provided with the charger. If outlet is not suitable for
safe use; have a properly grounded outlet installed by
a qualified electrician.
North America: Always use a properly grounded
3-wire extension cord, which has male and female
plugs. If 25 foot [7.6m] extension cords are used, the
electrical carrying capacity should be no less than 14-3
ST, 50 foot [15.2m] extension cords no less than
12-3 ST.

Grounding Instructions

This charger shall be grounded while in use to protect
the operator from electric shock. The charger is pro-
vided with a three-conductor cord and a three-contact
grounding type attachment plug. The plug must be
plugged into an appropriate outlet that is properly in-
stalled and grounded in accordance with all local codes
and ordinances. The green conductor in the cord is
the ground wire. Never connect this wire to other
than the grounding pin of the attachment plug.
If the cord provided with the charger has an attach-
ment plug as shown in Figure A. below, it is intended
for use on a nominal, 120-volt circuit. If a properly
grounded receptacle as shown in Figure A is not avail-
able, an adapter may be installed as shown in Figure B
if the outlet box that houses the receptacle is ground-
ed. Be sure to fasten the grounding tab (the green
colored rigid ear, lug or the like extending from the
adapter) with a metal faceplate screw.
If the cord provided with the charger has an attach-
ment plug as shown in Figure C, it is intended for
use on a nominal 240-volt circuit (single phase only).
Changes to the attachment plug or use of adaptors to
other plug types must be done in accordance with local
regulations.
Unplug battery charger from
Improper connection of the
NOTE: In Canada, the use of a temporary adaptor is
not permitted by Canadian electrical code, C22.1.

Unpacking Instructions

1.
Carefully cut the (2) bands from around the car-
ton.
Remove staples and open top flaps.
2.
Locate the rear of the machine where the pallet
3.
ramp is taped to the machine.
Remove staples at bottom of carton and lift carton
4.
from pallet. CAUTION-Stay clear of rear of carton
when lifting carton, the ramp can fall backward.
5.
Fold down ramp taking care that it rests complete-
ly and securely on the edge of the pallet.
Remove the lag bolts holding the (2) pallet an-
6.
chors to the pallet (7/16in wrench required).
Remove and read all operating instructions.
7.
Check that the key switch is off.
8.
Open the battery compartment.
9.
10. Plug the battery connector into the connector lo-
cated at base of control panel behind the batteries.
11. Check that the circuit breaker on rear panel is ON.
12. Turn on the keyswitch. The battery meter will light.
13. Taking care that the casters line up with the ramp,
slowly drive the machine backward off the pallet.
14. Recycle the carton and pallet.
Recycle the packaging.
Figure A
Figure B
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wrangler 2012 db

Table des Matières