IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be
followed including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before installation.
DANGER – Risque de choc – Couper l'alimentation avant
l'installation.
2.
This luminaire must be installed in accordance with the NEC or
your local electrical code. If you are not familiar with these codes
and requirements, consult a qualified electrician.
Ce produit doit être installé conformément à NEC ou votre code
électrique local. Si vous n'êtes pas familier avec ces codes et ces
exigences, veuillez contacter un électricien qualifié.
3.
Suitable for Damp Locations.
Convient aux emplacements humides.
4.
Access above ceiling required. Do not install insulation within
3 inches (76 mm) of any part of the luminaire.
Acces requis au-dessus du plafond. Ne pas mettre l'isolant a moins
de 76 mm (3 po) de toute partie du luminaire.
5.
Vapor barrier must be suitable for 90C.
Le pare-vapeur doit convenir pour 90 °C.
6.
No user serviceable parts.
Pieces non reparables par l'utilisateur.
7.
Inherently protected.
Protection inherente.
8.
Do not handle energized module with wet hands or when standing on
wet or damp surfaces, or in water
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
• The ZR-LDE1/LDE5 Series of recessed troffers is for non-insulated
ceiling applications using T-Bar ceiling grid, drywall grid adaptors,
and suspended mount.
• Designed for use in 120-277V 50-60 Hz protected circuit (fuse box,
circuit breaker). Supply wire sized as per NEC or governing code(s),
90C rated.
• Make sure to cap off all unused leads.
TO INSTALL:
1
1 of 3
T-Bar Clips
Lutron EcoSystem Controls
Specification Troffers with Removable Lens
Includes: ZR14-LDE1/LDE5, ZR22-LDE1/LDE5, ZR24-LDE1/LDE5
ZR14-LDE1/LDE5
ZR22-LDE1/LDE5
ZR24-LDE1/LDE5
• Lens and removable end cap may shift during installation. Press
center of lens to engage magnet strip and push the end cap against
the end panel to eliminate the gap after installation.
• IMPORTANT: To avoid damage to the lens or housing during
installation, make sure fixture is supported near the centers of both
long sides of the housing when lifting. Do not lift fixture from one
end only.
T-Bar Clip Hole
ZR Series with
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D'INSTALLATION
T- BAR CEILING MOUNTING
STEP 1:
Bring the ZR troffer into the T-bar
ceiling panel. See Figure 1 for location
of the T-bar clips on end panels of
troffer.
STEP 2:
Bend clips upward and rotate outward
to engage with T-bar support grid. See
Figure 2. Secure luminaire to grid in
compliance with state and local codes.
LPN00678X0005A0_B

Publicité

loading

Sommaire des Matières pour CREE LIGHTING ZR Serie

  • Page 1 ZR Series with Lutron EcoSystem Controls Specification Troffers with Removable Lens Includes: ZR14-LDE1/LDE5, ZR22-LDE1/LDE5, ZR24-LDE1/LDE5 INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS INSTRUCTIONS D’INSTALLATION When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS ZR14-LDE1/LDE5 DANGER- Risk of shock- Disconnect power before installation.
  • Page 2 Junction Box Cover T-Bar Clips bent upward, rotated outward, and engaged with the grid AC Wiring Chamber End Cap Dimming Wiring Arrow Marks Chamber DO NOT Rotate Lens Into This Arrow Marked Zone End Cap Fixed End Cap SUSPENDED MOUNTING STEP 3: After cleaning is complete insert lens back into fixed end cap.
  • Page 3 If dimming is not being used, ensure to cap off the lead. © 2020 Cree Lighting, A company of IDEAL INDUSTRIES. All rights reserved. For informational purposes only. Content is subject to change. See www.creelighting.com/warranty for warranty and specifications. Cree and the Cree logo are ®...
  • Page 4 Serie ZR con controles Lutron EcoSystem Especificación de luminarias fluorescentes con lentes removibles Incluye: ZR14-LDE1/LDE5, ZR22-LDE1/LDE5, ZR24-LDE1/LDE5 INSTRUCCIONES DE INSTALACIÓN MEDIDAS DE SEGURIDAD IMPORTANTES INSTRUCTIONS D’INSTALLATION Al usar aparatos eléctricos, siempre deben seguirse ciertas medidas básicas de seguridad, incluidas las siguientes: LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD ZR14-LDE1/LDE5...
  • Page 5 Tapa de la caja de conexiones Clips de la barra en T doblados hacia arriba, girados hacia afuera y enganchados con la rejilla Cámara de cableado de CA Tapón Cámara de cableado Marcas de flecha del atenuador NO gire el lente Tapón con marca hacia esta zona de flecha...
  • Page 6 Si no se está haciendo uso de esta, asegúrese de tapar el cable. © 2020 Cree Lighting, una empresa de IDEAL INDUSTRIES. Todos los derechos reservados. Para fines informativos únicamente. El contenido está sujeto a cambios. Visite www.creelighting.com/warranty para ver la garantía y las especificaciones. Cree y el ®...

Ce manuel est également adapté pour:

Zr14-lde1Zr14-lde5Zr22-lde1Zr22-lde5Zr24-lde1Zr24-lde5