Télécharger Imprimer la page

CREE LIGHTING ZR Serie Instructions D'installation page 2

Publicité

Les langues disponibles

Les langues disponibles

2
AC Wiring
4
Chamber
Dimming Wiring
Chamber
6
1
2
DO NOT Rotate
Arrow Marked
End Cap
SUSPENDED MOUNTING
STEP 1:
Attach customer supplied cables to the (4)
T-bar clips located in the corners of the
housing. See Figure 1.
NOTE: The hole in each clip should be used to
attach the cable
STEP 2:
Attach cables to mounting surface using
customer supplied hardware. Ensure that
mounting surface can support the luminaire.
WIRING AND DIMMING OPTION
STEP 1:
Remove the screw on the cover of the
junction box and bring in appropriate power
supply to the junction box using one of the
knock-outs. See Figure 3 and 4.
STEP 2:
Bring dimming conduit into dimming wire
compartment using one of the knock-outs
on the dimming side of the junction box. See
Figure 4 .
2 of 3
T-Bar Clips
bent upward,
rotated
outward, and
engaged with
the grid
Lens Into This
Zone
STEP 3:
Wire luminaire per "Electrical Connections"
section and push all leads into the junction
box. Reattach junction box cover that was
removed in Step 1. Make sure no wires are
pinched.
CLEANING LENS
STEP 1:
Locate the end cap with the arrow marks on
it, indicating that the end cap is removable.
See Figure 5.
STEP 2:
Grab the lens section next to the end cap and
pull lens and end cap together downward
gently until end cap just clears luminaire
(about 3" to 4" from original position). See
Figure 6.
STEP 3:
Disengage the other end of the lens from the
opposite end cap by pulling lens away from
end cap. See Figure 6. Once lens is removed,
perform cleaning.
STEP 4:
3
5
7
2
After cleaning is complete insert lens back
into fixed end cap. Push the removable end
cap upward into the housing and using a
gentle rocking motion engage the end cap to
retention clip. Check removable end cap for
any visible gap between the end cap and end
panel. If necessary push end cap against the
end panel to eliminate gaps.
Check lens for any visible gap between the
lens and luminaire. If necessary push lens
upward at gap location to seal magnetic foam
to luminaire. See Figure 7.
Junction Box
Cover
End Cap
Arrow Marks
1
Fixed End Cap
LPN00678X0005A0_B

Publicité

loading

Ce manuel est également adapté pour:

Zr14-lde1Zr14-lde5Zr22-lde1Zr22-lde5Zr24-lde1Zr24-lde5