INSTALLATION INSTRUCTIONS FOR HDN64 SERIES RANGE HOOD
READ & SAVE THESE INTRUCTIONS
PLANNING
This hood can be connected to ductwork to discharge through the top
or the back of the hood to outside. It can also be installed without ducts
to return filtered air back into the room. For a ductless installation, a
separate filter is required.
Order conversion kit FKM65.
Mounting height MUST BE at a minimum of 22" and at a maximum of
30" above the cooking surface from the bottom edge of the range
hood.
The hood shall be mounted to the bottom of a standard wall cabinet.
If the hood must be mounted directly to a wall, secure the hood to wall
studs.
All wiring must comply with local codes and the unit must be properly
grounded. Connection should be made to a 110-120 VAC lighting
circuit (15A) in the circuit breaker or fuse box.
IF THE RANGE HOOD IS TO BE DUCTED:
Ductwork can be installed vertically or horizontally.
Duct runs should be as short as possible.
Avoid the use of elbows.
Use metal duct tape at all joints.
Do not use duct smaller than the discharge on the hood.
NON DUCTED:
Disregard instructions for knockout.
Discard the transition, it will not be used.
PREPARATION
1. Use the dimensional drawing to lay out the range hood's mounting
holes, wiring access and ductwork.
2. Make cut-outs for wiring and ductwork.
3. If the hood is to be ducted, install the ductwork so that it is flush to the
range hood's mounting surface.
• Refer to Figure 1 if the range hood is to be installed with a horizontal
discharge.
• Refer to Figure 2 if the range hood is to be installed with a vertical
discharge.
4. Remove the necessary duct opening and wiring knockout from the range hood.
NOTE: If the range hood is to be installed as a ducted unit, install
baffle plate (refer to figure 4) by sliding into place behind
grille. Use locator bumps to orient the grille.
NOTE: If the range hood is to be installed as a ductless unit, do
not remove any knockouts.
5. Run two-conductor wires (with ground) from a power source to the hood
location. Bring approximately 12" of wiring through wiring hole in cabinet.
6. Drill four 3/32" diameter pilot holes at points where mounting holes are
marked in the filler strips or cabinet bottom.
7. Insert four (4) mounting screw (not supplied), leaving approximately
1/4" of thread exposed. Use no. 8 or no. 10 round head screws.
INSTALLATION
1. Refer to Figure 6 for a vertical discharge installation.
Secure the 3¼" x 10" transition (if used) to top of hood.
Refer to Figure 7 for a horizontal discharge installation.
If using the supplied 3¼" x 10" duct transition, remove the damper from
the transition to prevent possible venting interference. Position transition
into wall cutout (the transition does not fasten to the hood).
Refer to Figure 5 for 7" round discharge installation.
Secure 7" round adaptor to top of hood using screws provided.
2. Feed the wiring through the access hole and into the electrical box.
3. Align hood's keyhole mounting slots over the four (4) partially installed screws.
4. Making sure the duct position over the hood's duct transition (or adaptor),
push the hood against the rear wall. Secure hood by tightening screws.
5. Using a long blade screwdriver, reach into the discharge opening and
make sure the damper operates freely.
WIRING CONNECTIONS
All wiring connections must comply with local code and the unit must be
properly grounded.
1. Make sure box connector is secure.
2. Refer to Figure 8. Make wiring connections.
3. Replace electrical box cover and secure with screw.
LOCATORS
FIGURE 4
FIGURE 5
FIGURE 6
POSITION DUCT
TRANSITION IN
WALL CUTOUT
FIGURE 7
WHITE
BLACK
GROUND SCREW
FIGURE 8
2
BAFFLE
PLATE
7" ROUND
ADAPTER
(Not included)
SECURE TRANSITION
WITH SCREWS (included)
HORIZONTAL
WHITE
BLACK
GREEN OR BARE
(GROUND)