PARAMETERS

Keyword
Parameter
Description
Temperature Limit
SP
Setpoint
value
r0
Hysteresis
r1
SP Lower Limit
r2
SP Upper Limit
r3
Control Reset
Hi or Low limit
d0
control
Minimum
c0
Stopping Time
Output status for
c2
Probe Error
Alarm energize
c3
condition
Probe
P1
Adjustment
Thermocouple
P5*
Probe type
Type
Reading Refresh
P6
Probe response
interval
Display shown during
H1
Display Reading
normal operation
Keyboard
H5
Access Code
Security
* Be careful not to select the wrong sensor type.
Configuration of Parameters:
1.
Press and hold the (SET) button for approximately 8 seconds. Use (▲▼) buttons to input the
access code. Press (SET) to Enter.
2.
Use (▲▼) buttons to find the desired parameter. Once found, press (SET) to view or modify.
3.
Adjust parameter values by using (▲▼) buttons.
4.
Press the (SET) button to save the new value. The display will flash only the parameter keyword.
5.
Use (▲▼) buttons to select another parameter to modify using steps 2-4 above.
6.
To exit the programming mode, press (SET) and (▼) together. OR, wait 60 seconds for the
controller to automatically exit programming mode and show the Run display per H1.
In case H5 (the access code) is changed and forgotten, it can be reset to 0 by turning off control,
pressing down and holding (SET), and turning control back on. No other parameters will be changed.
®
© BriskHeat
Corporation. All rights reserved.
HL101 Series Digital Temperature Limit Control
Range
Units
Default
r1 to r2
°
1 to 99
°
0 to r2
°
r1 to 999
°
999
Aut: automatic reset
hoL: latch alarm, manual reset
hoL
PuP: must power cycle to reset
Hi / Lo
0 to 999
oFF/ on
oFF
no / Yes
-30 to 30
tcJ: J-type thermocouple
tcJ / tcK
tcK: K-type thermocouple
0: 8 sec
1: 4 sec
2: 2 sec
3: 1 sec
PV: Process Value
SP: Setpoint
7

MAINTENANCE INSTRUCTIONS

0
1
Maintenance:

0
Dirt, oil, grease or other foreign matter can be removed with a damp rag and mild household
cleaners. No solvents, abrasives, petrol, or alcohol.
NOTE: The device should be unplugged prior to cleaning with a damp rag and allow to fully dry before
Inspection:
Hi

Perform before and after use of the controller.
1

The cables and wires should not have any visible breaks in their insulation.

The casing and control should be free of any cuts, cracks or punctures.
Storage:
no

This product should be stored at room temperature in an environment with less than 80% relative
0
humidity.
Disposal:

This product must be recycled in accordance to 2012/19/EU Waste Electrical and Electronic