WARNIN G
!
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information
can result in death, serious personal injury, property
damage, or damage to the equipment.
Keep this Manual for future reference.
A DV ERTE N C I A
!
Lea este manual ANTES de utilizar este equipo.
El no leer y seguir todas las medidas de seguridad y
usar la información puede causar la muerte, lesiones
personales graves, daños materiales o daños en el
PIENSE
equipo.
PRIMERO EN
LA SEGURIDAD
Guarde este manual para referencia futura.
A VER TI S S E ME N T
!
Lisez attentivement ce manuel avant d'utiliser cet équipement.
Négliger de lire et de suivre toutes les consignes de sécurité
et d'utilisation de l'information peut entraîner la mort, des
blessures graves ou des dégâts matériels, ou endommager
LA SÉCURITÉ
l'équipement.
AVANT
Veuillez conserver ce manuel pour toute référence ultérieure.
TOUT
IS-D-FLOPRO-MD 1950
USA: T: (800) 367-6668 • F: (724) 733-4808 • Dormont.com
Canada: T: (905) 332-4090 • F: (905) 332-7068 • Dormont.ca
Latin America: T: (52) 55-4122-8600 • Dormont.com
EDP# 1915457
Instructions for Installing
Refer to the FloPro-MD Installation and Operation
Manual for complete product information, warnings
and install instructions
1. Turn off gas valve. Apply a gas approved pipe thread sealant or tape to all ¾" Male
NPT threads before mating.
2. Tighten the two shoulder nipples onto the FloPro-MD housing using a pipe wrench
and adjustable wrench.
3. Tighten the male QD nipple to the upstream side of the FloPro-MD and the female
QD coupler to the downstream side of the FloPro-MD as shown in Fig. A using two
adjustable wrenches.
4. Disconnect the female QD coupler of the Blue Hose SnapFast
appliance and connect it to the upstream end of the FloPro-MD male QD nipple.
5. Connect the downstream end of the FloPro-MD female QD coupler to the QD male
nipple on the appliance as shown in Fig C.
6. Ensure connections are leak tight by using an approved leak solution or sniffer.
Turn on gas valve.
Fig. A QD male nipple
installed on the upstream
end and QD female coupler
installed on the down-
stream end.
© 2019 Watts
with SnapFast
QD from the
®
Fig. B Existing Gas Range
Fig. C Gas Range outfi tted
with Blue Hose QD and
with the new FloPro-MD
Swivel Max combo.
with QD Kit.
IS-D-FLOPRO-MD
QD
®

Publicité

loading

Sommaire des Matières pour Watts DORMONT FloPro-MD IS-D-FLOPRO-MD

  • Page 1 USA: T: (800) 367-6668 • F: (724) 733-4808 • Dormont.com Canada: T: (905) 332-4090 • F: (905) 332-7068 • Dormont.ca Latin America: T: (52) 55-4122-8600 • Dormont.com IS-D-FLOPRO-MD 1950 EDP# 1915457 © 2019 Watts...
  • Page 2 Français Español Instructions pour l’installation de Instrucciones para instalar avec SnapFast con SnapFast ® ® Consulte el manual de instalación y funcionamiento del Consulter le manuel d’installation et d’utilisation du FloPro-MD para obtener información completa sobre el FloPro-MD pour obtenir des renseignements complets sur le producto, advertencias e instrucciones de instalación produit, des avertissements et des instructions d’installation.