LATICRETE LATAPOXY 310 Mode D'emploi page 8

Distributeur sans fil
Masquer les pouces Voir aussi pour LATAPOXY 310:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.
BATTERY AND CHARGING
Use only the 20V battery in the charger provided. Other battery types may cause personal injury and or damage. Please read the charging manual attached with this package for specific
information regarding safety and charging.
4.1 Charge battery to full capacity prior to use.
4.2 Charging time will vary according to voltage supply, the amount of the charge needed for that battery and temperature.
4.3 Temperature will affect battery life. It is best to charge when temperature is between 60° – 80° F (15° – 27° C). Do not charge when temperature drops below 40°F (5°C) or
above 105°F (40°C).
4.4 Estimate roughly 30 minutes to fully charge a battery
5.
TOOL SET UP AND LOADING
5.1 Open clutch lever, grasp rack handle and pull outward until fully open.
5.2 Remove protective tip by on top of cartridge and simply LATAPOXY
310 Stone Adhesive pry off to open both sides of cartridge.
5.3 Insert one LATAPOXY 310 Cartridge Pack into the Cartridge Housing,
pushing tip through the hole at end of housing.
5.4 Push rack forward until pistons make contact with back of cartridge,
close clutch.
NOTE: REMEMBER TO CONDITION THE MATERIAL TO AT
LEAST 65° F (18°C) PRIOR TO USING!
5.5 Screw mixing nozzle onto the thread tightly and you are ready to apply!
6.
DISPENSING
6.1 Squeeze trigger to begin dispensing material. Adjust the dispensing speed
as desired by turning the dial on side of tool. You will see the pink and
white components mix as they are pushed through the Mixing Nozzle.
Make sure material is uniform in color when dispensed from the nozzle.
6.2 Hold the Cordless Mixer at an angle on the tile or stone to be adhered.
Push the material into the stone by using a circle motion and using the
edge of the nozzle to "key" the material as it is dispensing.
Note: Cordless Mixer is equipped with an automatic reverse that engages
after trigger is released to reduce any leakage. Build height of dab as
needed to achieve plumb surface.
6.3 Apply dabs evenly distributed on back of the stone or tile; 5 dabs
minimum, each corner and center. Cover at least 10% of the area of
each piece (compressed dab). Finished dab thickness must be a
minimum of 1/8" (3mm).
Approximate dab diameter required to achieve 10% coverage with 5 dabs:
TILE/STONE SIZE
12" x 12" (300 mm x 300 mm)
24" x 24" (600 mm x 600 mm)
36" x 36" (900 mm x 900 mm)
NOTE: PULL OFF THE FIRST STONE INSTALLED TO MEASURE THE DIAMETER OF EACH DAB. ADJUST THE QUANTITY OF LATAPOXY
ADHESIVE TO ACHIEVE THE APPROPRIATE COVERAGE. ONCE THE CORRECT AMOUNT HAS BEEN DETERMINED, SET DOSING KNOB TO OBTAIN THE
CONSISTENT LEVEL FOR ALL VENEERS.
6.4 Dispense all the material until the rack drive is completely at the end of the cartridge and can not move any longer. You are now ready to remove the used cartridge and replace with
a new one.
TIP: EVALUATE THE WALL PRIOR TO INSTALLING THE VENEER, YOU'LL WANT TO SEE IF THERE ARE ANY AREAS SEVERELY OUT OF PLUMB. DROP A
LINE FROM THE TOP AND IDENTIFY ANY HIGH POINTS OR "SUNKEN IN" AREAS. MAKE SURE YOUR FIRST COURSE OR TWO CAN BE FOLLOWED ALL
THE WAY UP THE WALL, SO THAT YOU DON'T RUN INTO A HIGH POINT WHICH WILL BE OUT OF PLUMB WITH WHAT YOU JUST SET.
®
FIGURE 5.1
FIGURE 5.2
FIGURE 5.3
DAB DIAMETER
2" (50 mm) (each dab)
4" (100 mm) (each dab)
6" (150 mm) (each dab)
8
FIGURE 5.4
FIGURE 5.5
310 STONE
®

Publicité

Table des Matières
loading

Table des Matières