Change the Fuses in the Base Unit
DANGER
Risk of electric shock. Turn off power supply to equipment prior to working inside base unit.
CAUTION
• The electrical connections and conduit installations shall be made by a certified electrician
and in compliance with local regulations.
• Risk of fire. For continued protection against risk of fire, the fuses must be replaced
with the same type and rating.
1. Separate the pan/tilt unit from the base unit by removing the four screws, see section
Hardware Overview.
2. Check the fuses by using a multimeter. If the fuses are blown, change the fuses. See
the table below.
1
Pan/tilt unit
2
Base unit
3
Fuse F1
4
Fuse F2
Fuse Specification
Voltage
24/100 V AC 50/60 Hz
1
2
Fuse F1 5x20
F 6.3 A 250 V
23
AXIS Q86–E Series
3
4
Fuse F2 5x20
T 8 A 250 V