Troubleshooting - Bewator CD3500 Manuel D'installation Et De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CD3500 & CD4000 Installation and User manual

Troubleshooting

Symptom
Lock does not open when
code us entered.
Codoor is in unlocked
position.
Codoor does not sound
following key presses.
Batteries are rapidly
discharged.
Lock does not open even
though backup power.
Remedy
Check that the right code has been entered.
Make sure the handle is not pressed down as the
code is entered.
Check that the handle is not sagging.
Check that the time limit for automatic reset has
elapsed.
Check that Codoor is fitted exactly vertical.
Check that the lock is not fitted too tightly to the
door, in which case the handle could be jammed.
Check that the red mark on the follower for the
lever handle spindle is pointing downwards.
Set Codoor to locked position (if required)
according to the instructions in section
Deactivation function.
Activate the buzzer (see section Buzzer)
Frequent use requires frequent change of
batteries. The batteries last up to 150,000
openings (lithium-type) and 50.000 openings with
alkaline-type.
Check the batteries and change any discharged
batteries.
The blocking counter is activated. See section
Access blocking. Enter the programming code
(skip  before and after the code).
The batteries may be bad and should be changed
immediately.
The batteries are completely discharged and
should be changed immediately.