quiko QK-CE220CT Instructions Pour L'installation Et Manuel Du Propriétaire page 19

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

This solution is recommended when you want to enter a reserved area in both directions activating a recognition command
(radio control, proximity key, magnetic keys, etc.).
ENTRY
The vehicle approaches the re-
served area.
EXIT
Loops S1 and S2 also have a safety function in that they will not let the device move all the time the vehicle is on top.
DIMENSIONS
- Connect loops S1 and S2 in series to just one detector whose N.O. contact is wired to input 27-29.
- The dimensional values of the loops are only approximate. We suggest installing the QUIKO QK-LDT2 metal mass detector.
10.3 CONTROLLED ENTRY AND EXIT
- 19 -
When the vehicle is on loop S1 the
device will move down only after a
recognition command.
If the device is moving back up and
you want to lower it again the vehicle
must be on loop S1 and then you
must activate the recognition com-
mand.
When the vehicle is no longer on
loop S2 the device will move back
up automatically after an adjustable
pause time.
The vehicle approaches the reserved
area.
When the vehicle is on loop S2 the
device will move down only after a
recognition command.
If the device is moving back up and
you want to lower it again the vehicle
must be on loop S1 and then you
must activate the recognition com-
mand.
When the vehicle is no
longer on loop S1 the
device will move back
up automatically after an
adjustable pause time.
1
2
3
4 5 6
7 8 9 10
Setting the dip
switches

Publicité

Table des Matières
loading