Charging Your Batteries - Guest CHARGEPRO Serie Manuel Du Propriétaire Et Guide D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TYPICAL WIRING
23
Fig. 10 ChargePro
10/10/10/10 Quad Bank Charger for 4 12V Batteries
Dedicated 48 VDC propulsion system battery configuration
with (4) 12 VDC batteries connected with (3) series jumpers
Note:
Indicates Jumper Series
Indicates Fuse
ChargePro
Quad Bank
Cable 4
Cable 3
_
_
bat 4
bat 3
+
+
Four 12 VDC Batteries Connected with (3)
Series Jumper for a 48 VDC Trolling Motor
DANGER: RISK OF ELECTRIC SHOCK.
Do not touch uninsulated portion of output connector or uninsulated battery terminal
if 3 or more batteries are connected in series.
Charger
For Engine Battery
Use Cable 1
Cable 2
Cable 1
_
_
bat 2
bat 1
+
+

Charging Your Batteries

The ChargePro
Series is designed to charge, condition, and auto maintain your batteries during
short or long term periods of storage. Please follow these steps each time you use your
ChargePro
Series Charger:
1. Read manual and all warnings.
2. Review "Preparing to Charge a Battery" on page 6.
3. Ensure charger is installed as per the installation instructions.
4. Connect a heavy duty UL approved extension cord to the ChargePro
After connecting the extension cord to the charger, proceed to plug the extension cord to a
nearby 120 VAC GFCI protected (Ground Fault Circuit Interrupt) outlet. Anytime power is
applied to the ChargePro
Series the blue AC Power LED will illuminate.
5. The red Charge LED for each battery bank will flash indicating the charger is in Analyze
mode. It should be noted, Analyze mode can take up to 1 minute as the ChargePro
will do a self test to check wiring connections and make sure the batteries are
> than 4 Volts DC and are able to take a charge.
Assuming there are no battery faults, the following charger operation sequences
will proceed:
Note: If there is a bad connection, reverse polarity, or a battery that is below 4 VDC that
can not accept a charge then a RED Battery Trouble status LED will illuminate for the battery
that requires attention. See page 26 for further troubleshooting details.
6. The red charge mode LED for each battery bank will transition to a solid ON indicating the
charger has started its multi-stage charging process as outlined in the Multi-Stage Charging
Overview section of this manual.
CAUTION HOT SURFACE. Avoid contact during charging operation as unit will be hot to
the touch but operating safely and properly.
7. The red Charging mode LED for each battery bank will turn off and the Conditioning LED will
be solid amber indicating that the ChargePro
charging by conditioning each battery for up to 3 hours as needed.
8. When the charge process is complete (or if your batteries are fully charged when you apply
AC power) the green Auto Maintain (Energy Saver Mode) LED for each battery bank will
illuminate indicating your batteries are fully charged.
Note: The above applies to each individual charging output. Timing of LED status will vary
from battery to battery based on discharge state of the battery connected.
CHARGING YOUR BATTERIES
Series charger first.
will hold all batteries at 14.6 VDC to complete
24