SPACE HEATER 9 kW - Agricultural
GB
Operating Instructions
Connection
Connect the space heater to the mains supply using the plug
attached.
Operation (fig. 1)
Switch on the power outlet socket and turn the thermostat (2) to the
desired temperature. Press the button (1) to start the heater. Each
time the button is pressed the power setting changes.
Fig. 1
1
A
20 % power
B
60 % power
C
100 % power
D
Fan
Light in lamp (D) indicates that the fan has started. To switch off
the heater press the button (1) repeatedly until all lamps are off.
The space heater is equipped with an adjustable thermostat. The
temperature required is set by means of the adjustment button (2)
after which, the heater runs automatically. When the selected
temperature has been reached, the thermostat will disconnect the
current to the heating elements while the fan continues for approx. 2
minutes in order to after-cool the elements.
In event of overheating, the thermal cut-out will be activated.
When the heater has cooled down it will be necessary to restart the
heater.
In positions A, B and D the fan runs at reduced speed. In position
C the fan runs at full speed.
The space heater is equipped with a 0-volt trigger switch, which
means that in the event of a power failure, the heater must be
restarted by pressing button (1)..
WARNING !
Do not cover – danger of fire!
Do not place the heater where inflammable materials may
be placed on or near the heater!
Do not cover the heater, the heater must not be exposed to
excess dust and humidity!
Do not use the heater outdoors in rainy weather!
Do not place the heater directly under a mains outlet!
Do not use the heater close near to a bath, shower or
6
2
swimming pool!
When the heater is not in use, it must be removed from fire
hazardous rooms and should be stored in a dust-free
room!
The space heater must only be disassembled by the
manufacturer or a qualified service engineer!
The power cable must only be replaced by the
manufacturer or a qualified service engineer!
Fig. 2
Fixed installation (fig. 2)
When making a fixed installation the drawing must be followed ! Wall
bracket type 23200201 must be used.
Maintenance
Clean the space heater with compressed air when it is disconnected
from the mains.
External thermostat
The two connector points marked "TB" for external thermostat are
located under the top cover. Do as follows:
1.
Remove the two black wires, which connect the internal
thermostat to points "TB".
2.
Now connect the wires from the external thermostat to point
"TB".
The external thermostat should be of type Close = Heat..
GUARANTEE
KEEP VALID RECEIPT OR GUARANTEE CARD
To obtain guarantee cover within the guarantee period, it is an
absolute MUST that either a valid receipt or the guarantee card is
submitted to the service center together with the appliance.
Type 1880, 1882, 1890, 1892