Operating Instructions - Altrad BELLE PCEL 400E Manuel De L'opérateur

Masquer les pouces Voir aussi pour BELLE PCEL 400E:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
WARNING
WARNING
Take the compactor to where it is required.
DO NOT use a Mechanical Hoist on the Hand Lifting Points (See Machine Description section).
Transporting the PCEL 400E is a 2 person operation. Use the provided Hand Lifting Points (See Machine Description section)
NEVER leave the motor running whilst transporting or moving the PCEL 400E, even if it is only a short distance.
Having carried out the checks listed in the 'Pre-Start' section, you may start the motor.
Switch the machine on and use the control handle to steer or turn the PCEL 400E.
The vibrator will not only cause the baseplate to vibrate but will also cause it to travel forward. During normal operation you
should not have to push the PCEL 400E but allow it to travel at its own pace. The speed of travel will be determined by the
condition of the surface being compacted. If the surface to be compacted is on a slope, great care must be taken when controlling
the PCEL 400E's direction of travel. If necessary, use a suitable rope attached to the PCEL 400E at a low point on the chassis,
to allow a helper to take part of the PCEL 400E's weight. Work up and down a slope not across.
Work the PCEL 400E over the surface in an organized pattern until the required compaction has been achieved.
Where there are a number of different layers to be compacted on top of each other, compact each layer individually.
Stopping the Motor
1. Depress the RED Button (O) to stop the machine (Fig A).
Starting the Motor
1. Plug into power supply.
2. Depress the GREEN Button (I) to start the machine (Fig B).
Guide to using optional PCEL 400E Portable Appliance Test (PAT) Rig
WARNING
Prior to the PAT a Formal Visual Inspection must be carried out by a
competent person to check the electrical safety of the equipment following
correct procedure. For guidelines on PAT and de nitions involved please
visit government website:
http://www.hse.gov.uk/electricity/faq-portable-appliance-testing.htm.
1. Place the PCEL 400E plate compactor into the test rig / xture
(Part No. 968/01200) with the front of the plate facing the anti-vibration
mounts (Item 1), resting on the matting and with the handle swung back
(Fig C). The Test rig must be located on a level oor, in dry ambient
conditions with only the rubber feet touching the ground for appropriate
vibration damping (NOTE: rubber feet are NOT designed to isolate the
product from the ground) .
2. Fit the Z-Bracket (Item 2) (Part No. 968/01205) to the switch by sliding
it until it securely clicks into place and presses the green ON button
of the switch.
3. Connect an approved PAT tester, con guring it according to your PCEL 400E speci cations (e.g. Voltage; Appliance Insulation
Class; Correct type of test etc.).
4. Make sure that PCEL-E plate compactor and PAT test xture are not touched by a human, animal or any other object and are not at
risk of doing so during the test. Conduct the test when and if you are happy that it is safe to do so.

Operating Instructions

Before you operate or carry out any maintenance on this machine YOU MUST READ and STUDY
this manual.
NEVER pass over the electric cable with the compactor during operation.
Make sure that the plate is unplugged from the power source prior to carrying out rst steps or the visual
inspection!
FIG A
1
FIG C
12
FIG B
2

Publicité

Chapitres

Table des Matières
loading

Table des Matières