Terminal
2
Sealing Clamps
1
Sidewall Venting Breech Plate
2
Sealing Strips
1
Inner Wall Plate
1
Pressure Control with Tubing
2
Insulated Quick-connect Terminals
6
Self Tapping Stainless Steel Screws
3
Stainless Steel Screws
INSULATED FLEXIBLE VENTING - DV-2000™
The certified venting materials come in 3 lengths,
Model No.IFV3-15, IFV3-23 and IFV3-30 (or IFV4-15,
IFV4-23
and
IFV4-30
corresponding to 15', 23' and 30' continuous lengths of
vent.
The
vent
construction
incorporates an stainless steel corrugated flexible liner
surrounded by a thick insulation blanket and covered
with an outer layer of flexible corrugated aluminum
PORTION OF VENT
Vent pipe,from furnace breech to 1 foot downstream of furnace breech*
Vent pipe, up to vent terminal*
Sidewall venting
*Do not enclose venting
INSTALLATION CONSIDERATIONS - DV-2000™
Select a location for the vent terminal in accordance
with all local and national codes. The following
requirements shall be considered to be minimum
requirements that can be overridden by stricter local
and national codes:
A VENT SHALL NOT TERMINATE
a. directly above a paved sidewalk or paved
driveway that is located between two buildings,
and that serves both buildings;
b. less than 7 feet above any paved driveway;
c. within 6 feet of an opening window or door, or
mechanical air supply inlet to any building,
including soffit openings;
d. above a gas meter/regulator assembly within 3
feet of a vertical centerline of the regulator;
e. within 6 feet of any gas service regulator vent
outlet, or within 3 feet of an oil tank vent, or an oil
fill inlet;
f.
within less than 1 foot above grade level;
g. 6 feet of any other combustion air inlet;
h. within 6 feet of a property line;
i.
underneath a verandah, porch or deck;
j.
so that the flue gases are directed at combustible
material or any openings of surrounding buildings
that are within 6 feet;
for
160
models)
are
is
coaxial
and
Minimum clearances of sidewall venting system
sleeve to protect the insulation. Splicing vent
lengths together is prohibited. The maximum and
minimum continuous vent lengths permitted for
installation are;
5 feet minimum
Even though the flexible venting is insulated,
it cannot be run through an unheated space.
To do so could cause residual condensation
inside the stainless steel liner, which may
eventually perforate the liner and allow vent
gasses to enter the dwelling.
TABLE # 3
k. less than 3 feet from an inside corner of an L-
shaped structure;
l.
so that the bottom of the vent termination opening
is less than 1 foot above any surface that may
support ice, snow, or debris;
m. so that the flue gases are directed toward
brickwork, siding or other construction, in such a
manner that may cause damage from heat or
condensate from flue gases.
IMPORTANT:
notwithstanding
products of combustion shall not enter the
dwelling under any circumstances, even if all
other code requirements as to construction
and location have been complied with. The
installer is ultimately responsible to do
whatever is necessary to ensure that flue
gasses do not enter the dwelling.
INSTALLATION OF SIDEWALL VENTING - DV-
2000™
30 feet maximum
WARNING
CANADA
UNITED STATES
1/4"
ZERO
ZERO
ZERO
Most
codes
clause
that
states
3"
3"
have
a
that
7