Output module 2*relays 24V, analogue
Number of outputs
Output type settable
Relay output (solid state relay)
Analogue output
Galvanic isolation
Measuring transducer power sup-
ply
®
CALEC
energy master installation and operating instructions
Two
Relay functions:
Analogue functions: 0 ... 20 mA / 4 ... 20 mA
Test functions:
Max. contact voltage: 24 VDC
Max. current:
Frequency:
* Pulse width:
Duty cycle:
Normal state:
Leak current:
Current range
Accuracy
Max. load
50 V
24 VDC, max. 25 mA, short-circuit proof
Pulse / status / limit value / limit value 2
Relay test / analogue test
100 mA
max. 50 Hz at *
10 ms, 50 ms, 250 ms, 1 s
50%
Contact closed or open, settable
< 30 µA corresp. to > 800 kOhm at 24 VDC
0 ... 20 mA or 4 ... 20 mA
0.1% full scale, drift 50 ppm / K
R = (Uext - 4V) / 22 mA
settable
21