Location Mode For Easy Channels - Gewiss CHORUS GW 16 974CB Manuel De Programmation

Masquer les pouces Voir aussi pour CHORUS GW 16 974CB:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

To access the location mode for Easy channels, start from the thermostat's standard
operation screen and keep the button key
it is possible to locate the channels implemented by the device to enter them into the
various functions executed with the Easy configurator (Easy Controller). Use the circular
touch slider or the push-button
button key
to send the BUS command that enables the location of the channel
chosen: to signal the forwarding, the icon
the Easy channel location mode, you must press the button key
USER INSTRUCTIONS

Location mode for Easy channels

to select the channels to be located, then press the
SLA (Slave)
To be used to set:
• remotely, with other Easy devices, the type
(heating/cooling) and HVAC modes (or Setpoint) of
thermostat operation. The devices that can be used
include the Easy timed thermostat, the GSM Easy remote
control, the NAXOS Easy panel, the 4 Easy channels
interface, etc.;
• the thermostat's OFF mode, with priority over all other
controls, if the open window condition is detected by a
remote device. Upon signalling of closed window, the
thermostat returns to the previous operating mode or to
that of the last command received during OFF forcing;
• the storing/reproduction of max. 8 scenarios. The
thermostat memorises the current operating type, HVAC
mode and setpoint.
CDH (Heating command)
To be used to send the ON/OFF command to Easy actuators
that control the electrovalve for the heating system (if
separate logic) or for the heating/cooling system (if common
logic).
pressed for over ten seconds. In this mode,
lights up for a short period of time. To exit
74
.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Chorus gw 16 974cnChorus gw 16 974ct

Table des Matières