anti-tip block

NorMal INSTallaTIoN STepS
ANTI-TIP BLOCK INSTALLATION INSTRUCTIONS
electrical outlet location
To reduce the risk of tipping of the drawer, the Anti-Tip
block must be properly installed located 14 ³₄" above
the floor on which the Microwave In-A-Drawer™ will sit.
The 6" Anti-Tip block must be provided by the installer.
See Figures 2 and 6 for (24") or Figures 4, 5, and 6
(for 30"). The Anti-Tip block prevents serious injury that
might result from spilled hot liquids.
If the drawer is ever moved to a different location, the
Anti-Tip block must also be moved and installed. When
installed to the wall, make sure that the screws completely
penetrate the dry wall and are secured in wood or metal

Verifying package Contents

Remove all packing materials from inside the drawer.
DO NOT REMOVE THE WAVEGUIDE COVER, which is
located on the top of the Microwave In-A-Drawer™.
Sealing
Surface
Waveguide
Cover
Remove the feature sticker, if there is one. Check
the drawer for any damage, such as misaligned or
bent drawer, damaged drawer seals and sealing
surfaces, broken or loose drawer guides and
dents inside the cavity or on the front side of the
drawer. If there is any damage, do not operate
the Microwave In-A-Drawer™ and contact your
dealer or a DACOR AUTHORIZED SERVICER.
Figure 7
Design Specifications
4"

Installation Instructions

Sealing
Surface
Oven
Cavity
so that the block is totally stable. When fastening, be
sure that the screws do not penetrate electrical wiring
or plumbing.
5"
Figure 6

electrical outlet

electrical outlet location
Figure 8
The electrical requirements are a 120 volt 60 Hz, AC
only, 15 amp. or more protected electrical supply.
It is recommended that a separate circuit serving
only this appliance be provided.
The drawer is equipped with a 3-prong grounding
plug. It must be plugged into a wall receptacle that
is properly installed and grounded. Should you only
have a 2-prong outlet, have a qualified electrician
install a correct wall receptacle.
NOTE:
If you have any questions about the grounding or
electrical instructions, consult a qualified electrician
or service person.