ANEMOMETER
ANEMOMETER WITH CREPUSCULAR SENSOR
CREPUSCULAR
RAIN SENSOR
Anemometer or
Anemometer with
crepuscular sensor
ANEMOMETER:
universal device for measuring wind speed. Easy to install and control, this is an excellent and elegant system for protecting your awning; when the wind exceeds a set
threshold it closes/rewinds your awning. This sensor consists of a fixed part (casing containing electronics on a special support) and a mobile part (rotating axis with 3 blades). The device
should be installed in a place where the wind can be measured and not therefore behind walls or other protections. To fit the sensor, secure the retention plate using the 4 screws and wall
anchors, and then fasten the anemometer by sliding it in the special guide. Finally. Connect up to the MINI TS or MINI TS 2nd edition unit.
The sensor is supplied with two-pole shielded cable: one white pole or braiding for connecting up the positive power voltage lead (Terminal 7 of the MINI TS unit or terminal 1 of the
MINI TS 2nd edition unit or terminal 2 of the MINI TS SV unit or terminal 5 of the MINI TS SV 2nd edition unit) and a green pole or core for the output signal to be connected to
terminal 6 of the MINI TS unit or terminal 4 of the MINI TS 2nd edition unit or terminal 3 of the MINI TS SOLO VENTO unit or terminal 4 of the MINI TS SV 2nd edition unit.
When wiring up, keep to the diagram shown in the MINI TS or MINI TS 2nd edition or MINI TS SV or MINI TS SV 2nd edition unit instructions.
ANEMOMETER WITH CREPUSCULAR SENSOR:
The light intensity read by the sensor is translated into an analogue signal in current (4...20mA) proportionately to the read value (4mA = dark, 20mA = bright light). The device is supplied
with a 4-pole cable: two for the light sensor and two for the wind sensor, according to the following colours:
white = power supply positive pole, to be connected to terminal 7 of the MINI TS unit or to terminal 1 of the MINI TS 2nd edition unit or to terminal 5 of the MINI
WIND SENSOR:
TS SV 2nd edition unit.
green = output signal, to be connected to terminal 6 of the MINI TS unit or to terminal 4 of the MINI TS 2nd edition unit or to terminal 4 of the MINI TS SV 2nd
edition unit.
red or blue = power supply positive pole to be connected to terminal 8 of the MINI TS unit or to terminal 1 of the MINI TS 2nd edition unit.
LIGHT SENSOR:
yellow = output signal to be connected to terminal 9 of the MINI TS unit or to terminal 7 of the MINI TS 2nd edition unit.
When wiring up, keep to the diagram shown in the MINI TS or MINI TS 2nd or MINI TS SV 2nd edition edition unit instructions.
CREPUSCULAR SENSOR:
sensor for reading ambient light. To be connected to the MINI TS or MINI TS 2nd edition unit. It opens the awning in the presence of sunlight. This device
must not be shaded by lean-tos, balconies, etc., otherwise it is unable to read the intensity of the sunlight. Cable connection (Also see connection diagrams):
Terminal 1 = + Power supply, connect to terminal 8 of the MINI TS unit or to terminal 1 of the MINI TS 2nd edition unit
Terminal 2 = Signal output, connect to terminal 9 of the MINI TS unit or to terminal 7 of the MINI TS 2nd edition unit
BE CAREFUL NOT TO REVERSE THE POLES !! When wiring up, keep to the diagram shown in the MINI TS or MINI TS 2nd edition unit instructions.
RAIN SENSOR:
universal device for reading rain intensity and signalling this to the MINI TS or MINI TS 2nd edition unit.
The output signal is of the ON/OFF type in current (ON = rain = 20mA, OFF = no rain = 10mA) The switchover lever can be set by the skilled personnel (installer) by means of an
adjustment trimmer accessible by opening the plastic box. When making the setting consider:
a) With the trimmer set at maximum, output signal transition occurs with heavy rain.
b) With the trimmer set at minimum, the output transition signal occurs with lighter rain.
The sensor also features an internal heater that can be powered separately and which is useful during the winter to prevent the formation of ice on the sensitive part of the device, thus
jeopardising correct operation. Connections:
Terminals 1 and 2 = Connect to external power supply 12-24 V dc/ac - 2W
= Power supply, connect to terminal 8 of the MINI TS unit or to terminal 1 of the MINI TS 2nd edition unit
Terminal 3
Terminal 4
= Signal output, connect to terminal 10 of the MINI TS unit or to terminal 10 of the MINI TS 2nd edition unit
BE CAREFUL NOT TO REVERSE THE POLES !! When wiring up, keep to the diagram shown in the MINI TS or MINI TS 2nd edition unit instructions.
To MINI TS terminal 9 V-
or to MINI TS 2nd edition terminal 7 V-
To MINI TS terminal 8 V+
or to MINI TS 2nd edition terminal 1 V+
Do not change this
trimmer setting
Crepuscular control unit
Rain sensor
same as above as regards reading of wind force, this unit also features a sensor for reading ambient light.
WIRING DIAGRAMS
To MINI TS terminal 8 or to MINI TS 2nd edition
To MINI TS terminal 10 or to MINI TS 2nd edition terminal
25014 CASTENEDOLO (BS) - ITALY
Via Matteotti, 162
Tel. +39.030.2135811
Fax +39.030.21358279
www.ribind.it - ribind@ribind.it
code ACG2275
code ACG2276
code ACG2270
code ACG2271
To external power supply 12/24
Vac/dc
terminal 1
Rain Sensor control unit
10
Crepuscular sensor
Rain sensor thre-shold
adjustment trimmer