Anleitung_IW_160_SPK7__ 02.07.14 08:14 Seite 15
U 0
Rated idling voltage
I 2
Welding current
Ø mm
Electrode diameter
Symbol for falling characteristic
curve
Symbol for manual arc welding
with sheathed rod electrodes
Single-phase mains connection
Do not store or use the
appliance in wet or damp
conditions or in the rain.
Thoroughly read and understand
the operating instructions prior to
using the welder.
IP 21 S
Protection type
H
Insulation class
X
On-load factor
Symbol for TIG (tungsten inert
gas) welding
The set is interference-suppressed in compliance
with EC Directive 2004/108/EEC.
Mains connection
Idling voltage (V)
3 ~
Power input
Fuse (A)
Weight
Welding with coated rod electrodes
Welding current
Duty cycle X
25%
60%
100%
TIG welding
Welding current
Duty cycle X
25%
60%
100%
max. 160 A
230 V ~ 50 Hz
16 A
80
5,23 kVA at 22,74 A
16
9,8 kg
20 - 150 A
150 A
105 A
20 A
20 - 160 A
160 A
103 A
80 A
The welding times apply for an ambient temperature
of 40° C.
5. Fitting the carrying strap (Fig. 3/4)
Attach the carrying strap (11) as shown in Fig. 3/4.
6. Starting up
Connecting to the mains power supply
Before you connect the power cable (7) to the mains
power supply, make sure that the data on the rating
plate is the same as that for your mains supply.
Important! The mains plug may only be replaced by
a qualified electrician.
Important.
The welding set may only be connected to a correctly
installed earthed socket with a maximum fuse rating
of 16 A.
Connecting the welding cable (Fig. 5)
Important: Always make sure the device is
unplugged before carrying out any connection work
on the welding cable (8/9)!
Connect the welding cable as shown in Fig. 5. To do
so, connect the two connectors on the electrode
holder (8) and the ground terminal (9) to the
corresponding quick-lock couplings (5/6) and lock the
connectors in place by turning them in a clockwise
direction.
The cable with the electrode holder (8) is normally
connected to the positive pole (5) and the cable with
the ground terminal (9) to the negative pole (6) for
welding with coated rod electrodes.
Switching ON/OFF (Fig. 1/2)
Switch on the machine by moving the On/Off switch
(13) to the "I" position. The indicator lamp for
operation (3) then comes on. Switch off the machine
by moving the On/Off switch (13) to the "0" position.
The indicator lamp for operation (3) then goes out.