Flash DIGI 2 HF Mode D'emploi page 15

Thermostat programmable sans fil et recepteur mural
Masquer les pouces Voir aussi pour DIGI 2 HF:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Temporary
temperature
modification
In automatic mode this very useful function allows
you to modify ambient temperature temporarily.
• To increase the temperature, press the
(several times, if necessary).
• To decrease the temperature
press the
-
button (several
times, if necessary).
The current temperature level
indicator (comfort or reduced) will begin flashing.
This modification ends with the next change in
programmed temperature.
To return to the initial programme press
L
and re-position the pointer
under Auto.
The current temperature level indicator (comfort
or reduced) will stop flashing when the temporary
modification comes to an end.
Prolonged
absence
(holidays)
This mode protects your dwelling from freezing by
maintaining a minimum adjustable temperature in
your dwelling during your absences.
You can programme the length of your absence so
that the temperature rises for your return.
2 different settings are available for
maintaining temperature above frost level:
Permanent frost protection
button, the day 0I flickers.
• Press the
• Press once the
-
button, the F
ORC
• Validate with the
OK
button.
• Using
+/-
buttons, set the temperature level
desired during your absence.
• Validate with the
OK
button.
To cancel and return to Auto mode, press
button.
Setting frost protection temperature for a
certain number of days
• Press the
button, the day 0I flickers.
• Using
+/-
buttons, set the length of your absen-
ce in days (from 1 to 99 days). The current
day count as one.
• Validate with the
OK
button.
• Using
+/-
buttons, set the temperature level
desired during your absence.
• Validate with the
OK
button.
To cancel and return to Auto mode, press
button.
Installation maintenance signal
0000
h
This mode allows you either:
• to take steps for regular maintenance (change
of air conditioning filter, device cleaning).
• to compare your heating or air conditioning
consumption from one year to the next (by
comparing the number of running hours).
Counting running hours
Auto Manu
1
2
3
4
5
6
+
timer
-
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
DAYS
PROG
OK
1-7
P1-P4
0000
Press the
button.The display panel will
h
ndicate the number of hours your burner, air
conditioning,ventilator-convector,etc.(depending
of the type of device controlled) has been running
from the moment the batteries were inserted (by
pressing once on
+
or
-
you return the counter
to zero.).
Press the
MODE
button to return in Auto mode.
Programming the regular servicing of your
installation.
Press the
Set the number of running hours after which the
warning signal should flash using the
+
button
Validate with the
Auto Manu
begins.The message timer will appear at the end
+
¡c
of the count-down warning you that servicing is
required.
¡c
-
Possible settings
0
1
2
3
4
5
Various settings can be made on
the back of the device (when it is
not mounted).
MODE
1- Selection of installation's type
I
Heating
mode
2- Selection of adjustment mode
I
On/Off
The proportionnal mode is to be set when using
floorheating (high inertia).
3- Anti-locking function for the circulation
pump (activation of the pump for 1 minute
every 24 hours)
I
Anti-locking
display flickers.
function off
Configuration
MODE
In order to associate the transmitter with the
receiver:
• Press the receiver's
than 3 seconds.
MODE
• The indicator
release the pushbutton.
The system is in configuration mode.
• Press the
the transmitter Thermoflash DIGI 2 HF.
• The indicator
at the end of 5 secondes.
The transmitter/receiver link is now established.
Reset
For clearing all transmission/reception links:
• Press the receiver's pushbutton
than 10 seconds.
7
• The indicator
MODE
more quickly.
• Press again the receiver's pushbutton
than 3 seconds.
0000
• The indicator
h
Res
links have been cleared.
The receiver returns to the Auto mode.
Priority setting
Manual control is provided for this product.
• Press shortly receiver's
Each press reverses output state.
Note:
radio control retains priority.
0000
button.
h
+/-
buttons.
OK
button; the countdown
Cooling
I
Proportionnal
I
Anti-locking
I
function on
pushbutton for more
OK
light will start flickering,
RESET
button during 3 seconds of
OK
button will stop flickering,
for more
OK
light flickers slowly, then
OK
light stops flickering, all
pushbutton (<3 sec).
15
Troubleshootings
• The heating does not start:
- receiver's power supply is cut off
light is off). Check fuse and circuit breaker.
• Receiver is outside of transmitter's
range:
- move transmitter closer to receiver.
• Receiver does not recognize transmitter's
code:
- re-install receiver.
• The system does not start or does not stop:
- the receiver or transmitter is disturbed by radio
transmission (radio ham, TV monitor, cellular
phone re-transmitter, etc.): attempt to remove
the source of disturbance.
In case of persistent problem,call on your electrician.
Technical specifications
Transmitter
Adjustment range for comfort temperature:
Adjustment range for reduced temperature:
Adjustment range for frost protection temperature:
Display range for ambient temperature:
Static differential:
Power:
2 standard LR6 alkaline batteries
(to supply the product and the radio transmission)
Operating range: 75 m from transmitter to receiver
in a free field (operates over 3 building floors)
Transmission frequence:
Transmitter duty cycle:
IP:
Operating temperature:
Storage temperature:
Hygrometry:
Dimensions:
Degree of pollution:
Standards:
Receiver
Supply voltage:
Minimum load:
Output: 1 changeover contact free of potential
Switching capacity:
AC1:
Inductive:
Radio frequency:
Degree of protection:
Isolation class:
Mechanical protection:
Operating temperature:
Storage temperature:
Flexible capacity:
Rigid capacity
Dimensions:
Hygrometry:
Receiver class:
Standards:
Standards:
EN 301-489-1 and EN 301-489-3.
more
Usable everywhere in Europe
(OK
+5°C to +30°C
+5°C to +30°C
+5°C to +30°C
0°C to +40°C
< 0.3 K
433.92 MHz
10%
30
0°C to +40°C
–20°C to +70°C
95% max. at 25°C
115 x 82 x 34 mm
standard
EN 301-489-3
230 V +10 % at -15 %
12 V 100 mA
16 A 250 V
ϕ
3 A (cos
= 0,6)
433.92 MHz
IP43
II
IK04
-10°C to +60°C
-20°C to +70°C
0,5 to 1,5 mm
2
0,5 to 2,5 mm
2
130 x 60 x 27 mm
90% max. at 20°C
2
EN 60669-2-1
EN 300220-3,

Publicité

Table des Matières
loading

Produits Connexes pour Flash DIGI 2 HF

Ce manuel est également adapté pour:

56460

Table des Matières