General Warnings - IPC Eagle HighPure HP 0 Manuel D'instructions

Masquer les pouces Voir aussi pour HighPure HP 0:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Machine setup procedure:
Take inventory of the following items shipped along with the
unit.
Qty. 1 - RO membrane.
Qty. 1 - DI resin cartridge.
Qty. 1 - Sediment filter, 5 micron.
Qty. 1 - Carbon block filter
Qty. 1 - Large filter housing wrench
Qty. 1 - Small filter housing wrench
Qty. 1 - Tee pipe cap removal tool
Qty. 1 - 100 ft. hose for pure water to pole
Qty. 1 - Magic Lube - O-ring lubricant
Qty. 1 - TDS meter.
Install membrane, prefilters and DI cartridge as for instruction
following.
RO Membrane installation (fig. 2):
1. Remove the safety insert on the top of the pressure vessel
by unscrewing the screw or knob provided.
2. Using your fingers, grab the tab on the white plastic snap ring
and pull towards the center to remove.
3. Screw the tee pipe cap removal tool into the cap on top of
the pressure vessel.
4. Rock tool back and forth to unseat cap. Lift up and remove
cap and O-ring.
5. Remove RO membrane from sealed bag.
6. Note: The reverse osmosis membrane must be inserted
into the pressure vessel with the flat base (and the lip seal)
facing upwards, and the alignment pin downwards.
7. Apply a thin film of O-ring lubricant on to the seats at the ends
of the reverse osmosis membrane.
8. Carefully position the reverse osmosis membrane in the
pressure vessel, press downwards until resting firmly in its seat.
9. Apply a thin film of lubricant onto the cap's O-ring and place
this on the vessel.
10. Firmly press cap down into the top of the pressure vessel
until it is seated.
11. Replace white plastic snap ring into the groove. Start with
the tail end and work in around towards finger tab end. Ensure
that it is fully seated all the way around the entire diameter.
12. Place the safety insert on the top of the tab portion of the
snap ring.
13. Fasten it using the knob or screw provided.
Prefilters installation:
Filters placement: as you face the unit from the front (fig. 3):
- The 5 micron sediment filter is the first filter the feed water
goes through. Install it in the housing on the right side, next to
the water supply hose inlet fitting.
- The carbon block filter is the second stage filter and goes into
the housing on the left side.
1. Slide the small filter housing wrench up from under the bottom
of the white housing and turn CCW to loosen. Remove the tool
and spin housing completely off.
2. Lubricate both O-rings on housing with Magic Lube O-ring
lubricant.
3. Remove plastic wrapping on new filter. Position center hole
on shouldered ring on bottom of Pressure gaugehousing.
4. Screw housing into base and tighten with small filter hous-
ing wrench.
5. Repeat steps 1 - 5 for the second filter.
English
DI resin cartridge installation:
1. Slide the large filter housing wrench up from under the bottom
of the gray housing and turn CCW to loosen. Remove tool and
spin housing completely off.
2. Lubricate O-rings on housing with Magic Lube O-ring lu-
bricant.
3. Remove cartridge from the sealed bag and place into housing
with seal washer in the up position and locate the bottom hole
on shouldered ring inside the bottom of the housing.
4. Screw housing into base and tighten with filter housing
wrench.
Water circuit connection (fig. 4-5):
The machine may be operated standing upright or lying down.
Choose the position that offers the most stability at the job
site.
Chose a location close to the water supply tap if possible.
Extention garden hoses may be used but must be 5/8 inch
inside diameter or larger to minimize line pressure loss. Addi-
tional extention garden hoses may decrease system volume
production rate.
1. Connect water supply garden hose to feed water inlet
connection.
2. Connect the 100 ft (30 m) hose to pure water outlet con-
nection.
3. Direct waste water hose to an area that can accept the
water such as shrubs, trees, grass or drainage that leads to
a storm drain. Attach an extra garden hose if needed to reach
the desired area.
Note: The waste water will not harm any plant life. It is just
tap water with a higher total dissolved solids content.
Electrical connection (Vers. E).
The equipment should be connected to the mains in accordance
with current legislation.
Make sure the mains voltage corresponds to the voltage re-
quired by the appliance and indicated on the ratings plate.
Protect the electric cable from accidental crushing.
Failure to respect the above conditions absolves the
manufacturer from all liability and represents negligent
use of the product.
Protection against accidental contact.
Before removing the panels, unplug the appliance from the
mains. Before using the appliance, make sure the panels are
correctly assembled and fixed.
Failure to respect these instructions could result in electric
shock and absolves the manufacturer from all liability.

GENERAL WARNINGS

1) When using any electrical appliance, certain fundamental
rules should be respected:
• do not touch the appliance with wet hands or feet;
• do not use the appliance with bare feet or unsuitable clothing;
- 16 -
!
!

Publicité

Table des Matières
loading

Produits Connexes pour IPC Eagle HighPure HP 0

Ce manuel est également adapté pour:

Highpure hp eHighpure hp b

Table des Matières