Protective Features

Low Voltage Alarm (Red LED on Inverter) – This state is not harmful to the
Inverter, but could damage the power source. The Inverter shuts off when the
input voltage drops to 10.5 volts and an audible alarm sounds same time.
When ample power is supplied, the Inverter may then be turned back on.
Over-Voltage Protection (Red LED on Inverter) - The Inverter will
automatically shut down when the input voltage exceeds 15.8±0.5V volts DC
Overload Protection (Red LED on Inverter) The Inverter will automatically
shut down if the continuous draw exceeds its maximum wattage rating. When
the Inverter is at or near maximum output, an alarm will sound. When the
alarm sounds you need to disconnect the device(s) to bring the Inverter output
down to an acceptable level. If you continue to use the Inverter at or near the
maximum output, it will eventually overheat and shut down. If you exceed the
maximum Inverter output, the alarm will sound and the Inverter will
automatically shut down. The red fault indicator will light and the alarm will
continue to sound. The Inverter must be reset after an overload condition.
Temperature Protection
The Inverter is equipped with a cooling fan. Depending upon the load output
and the temperature of the Inverter, the cooling fan will turn on and off as
required to cool the Inverter if needed. If the temperature reaches
approximately 80°C the Inverter will shut down automatically. Turn off the
Inverter and allow it to cool for a minimum of 15 minutes. Before starting up
again, verify the total wattage of the devices being powered.
To Reset the Inverter
1. Turn off the Inverter using the ON/OFF switch on the Inverter, depending
upon how the Inverter was controlled.
2. Unplug all devices.
3. Turn the Inverter back on using the ON/OFF switch on the Inverter. Before
devices are reconnected, verify the total wattage of the devices to ensure they
are less than the rating of the Inverter.