SETUP & OPERATION

BEFORE YOU START

Compatible Compressor & Air Tool - Guidelines for Proper Usage & Operation
Always ensure the use of appropriately matched air tools and compressors. Be sure
that the air compressor being used can supply the appropriate volume, pressure and
delivery rate of air to the tool(s) without running continuously. Using tools or
combinations of tools that together or separately require more than the air compressor
can deliver will reduce performance and could void the compressor or tool warranty.
AIR SYSTEM (Fig.2)
Quick
Connector
Air Hose
1.
Always use clean, dry, regulated compressed air at 60 to 100 PSI.
2.
Do not exceed the maximum and minimum pressures. Operating the tool at the
wrong pressure (too low or too high) will cause excessive noise or rapid wear.
3.
Keep hands and other parts of the body away from the tool's discharge and
working areas when connecting the air supply.
4.
It is recommended that a filter-regulator-lubricator be used, and that it be located
as close to the tool as possible.
5.
If a filter-regulator-lubricator is not installed, place up to 6 drops of compressor oil
into the NPT inlet plug before each use.
6.
If a filter-regulator-lubricator is installed, keep the air filter clean. A dirty filter will
reduce the air pressure to the tool, which will cause a reduction in power,
efficiency, and general performance.
7.
For optimal performance, install a quick connector to the tool and a quick coupler
on the hose, if applicable.
8.
Verify that all of the connections in the air supply system are sealed in order to
prevent air from leaking.
OPERATING THE AIR MINI DIE GRINDER
WARNING: Read all instructions in this manual carefully and understand them
thoroughly before using the die grinder.
1.
Connect the tool to the air hose.
2.
Depress the trigger in order to operate the tool.
3.
Verify that the air supply is clean, and that it does not exceed 90 PSI while
operating the tool. If the air pressure is too high or air is unclean, it will shorten the
life of the tool, and may be dangerous.
4.
The air flow can be regulated by adjusting the flow valve at the base of the
handle.
Do not apply additional or excessive force to the tool when grinding.
Do not allow the die grinder to run free for an extended period of time. Doing so will
shorten the life of the die grinder.
Lubricator
Quick
Coupler
Regulator
Filter
Compressor
Cut-off
valve
Air
Fig.2