5 Specifications
BlueSolar charge controller
Battery voltage
Maximum battery current
Maximum PV power, 12V 1a,b)
Maximum PV power, 24V 1a,b)
Automatic load disconnect
Maximum PV open circuit voltage
Peak efficiency
Self consumption
Charge voltage 'absorption'
Charge voltage 'float'
Charge algorithm
Temperature compensation
Continuous/peak load current
Low voltage load disconnect
Low voltage load reconnect
Protection
Operating temperature
Humidity
Data communication port
Colour
Power terminals
Protection category
Weight
Dimensions (h x w x d)
1a) If more PV power is connected, the controller will limit input power to
200W resp. 400W.
1b) PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter minimum PV voltage is Vbat + 1V.
12/24 V Auto Select
200 W (MPPT range 15 V to 70 V)
400 W (MPPT range 30 V to 70 V)
Yes, maximum load 15 A
75 V absolute maximum coldest conditions
74V start-up and operating maximum
14,4 V / 28,8 V
13,8 V / 27,6 V
multi-stage adaptive
-16 mV / ° C resp. -32 mV / ° C
11,1 V / 22,2 V or 11,8V / 23,6V
or BatteryLife algorithm
13,1 V / 26,2 V or 14 V / 28 V
or BatteryLife algorithm
Battery reverse polarity (fuse)
Output short circuit
Over temperature
-30 to +60° C (full rated output up to 40° C)
100 %, non-condensing
See the data communication white paper
on our website
ENCLOSURE
Blue (RAL 5012)
6 mm² / AWG10
IP65 (electronic components)
100 x 113 x 40 mm
MPPT 70/15
15 A
98 %
10 mA
15A / 50A
VE.Direct
0,5 kg
7